EUVIMEDEUVIMED entdecken
Crossref

Automated detection of sheep eye temperature using thermal images and improved YOLOv7

Yadan Zhang, Gang Liu, Jun Wang

Computers and Electronics in Agriculture · 2025-03 · 230 · 109925

DOI: 10.1016/j.compag.2025.109925 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computers and Electronics in Agriculture, 2025-03. Verfasst von Yadan Zhang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Key Technologies Research and Development Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Infrared thermography for non-contact measurement of eye temperatures effectively reduces sheep stress, lowers labor costs, and improves detection efficiency. This study aims to evaluate the practicability and feasibility of replacing manual annotation with an improved YOLOv7 automated detection method for sheep eye temperature. The proposed SE-SC-YOLOv7 algorithm achieves a precision of 99.5 %, recall of 99.3 %, FPS of 99.3, AP 0.5 of 99.7 %, and mAP0.5 :0.95 of 73.3 %. This mAP0.5 :0.95 outperforms Centernet, Faster-RCNN, SSD, and YOLOx by 7.32 %, 30.20 %, 11.40 %, and 7.79 %, respectively. The mean absolute error of the maximum eye temperature between the SE-SC-YOLOv7 algorithm and manual annotation is 0.033℃, which is 16.24 %, 60.29 %, 6.54 %, and 18.58 % lower compared to the Centernet, Faster-RCNN, SSD, and YOLOx algorithms, respectively. Additionally, Spearman correlation analysis shows that the maximum, minimum, and average eye temperatures detected by the SE-SC-YOLOv7 algorithm are highly correlated with the manually annotated temperatures ( rho = 0.989, P < 0.001. rho = 0.922, P < 0.001. rho = 0.963, P < 0.001). The paired samples Wilcoxon signed-rank test demonstrates no significant difference between the eye temperatures detected by the SE-SC-YOLOv7 algorithm and manual annotation. The Bland-Altman consistency test proves that at the 95 % significance level, the SE-SC-YOLOv7 algorithm can reliably replace manual annotation. Therefore, the proposed method undoubtedly offers a promising solution for effectively detecting sheep eye temperature.

Förderung

  • National Key Research and Development Program of China
  • Key Technologies Research and Development Program

Zitieren

APA

Zhang, Y., Liu, G., & Wang, J. (2025). Automated detection of sheep eye temperature using thermal images and improved YOLOv7. Computers and Electronics in Agriculture, 230, 109925. https://doi.org/10.1016/j.compag.2025.109925

Vancouver

Zhang Y, Liu G, Wang J. Automated detection of sheep eye temperature using thermal images and improved YOLOv7. Computers and Electronics in Agriculture. 2025;230:109925. doi:10.1016/j.compag.2025.109925

BibTeX
@article{Zhang2025,
  author = {Zhang, Yadan and Liu, Gang and Wang, Jun},
  title = {Automated detection of sheep eye temperature using thermal images and improved YOLOv7},
  journal = {Computers and Electronics in Agriculture},
  year = {2025},
  volume = {230},
  pages = {109925},
  doi = {10.1016/j.compag.2025.109925}
}