Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography
Computer Methods and Programs in Biomedicine · 2026
DOI: 10.1016/j.cmpb.2026.109559 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026. Verfasst von Gabriela Grońska und 5 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering, Eindhoven University of Technology, De Groene Loper 19, Eindhoven, 5612 AP, North Brabant, The Netherlands. Electronic addres…. Hauptthemen laut MEDLINE: Artifacts, Electrocardiography, Electromyography, Diaphragm. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technische Universiteit Eindhoven.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVE: Accurate extraction of respiratory diaphragmatic electromyography (dEMG) is hindered by electrocardiographic (ECG) interference, motion artifacts, and noise. Existing methods, although effective, may remove physiologically relevant information. To enable robust ECG and artifact suppression while maintaining respiratory-related amplitude variations, a higher-order singular value decomposition (HO-SVD) based approach was developed. METHODS: The HO-SVD algorithm exploits the multidimensional structure of dEMG recordings by jointly decomposing the temporal, overlapped QRS complexes, and spatial (channel) dimensions. The method enables targeted suppression of coherent and repetitive artifacts prior to signal reconstruction. Performance was evaluated on three synthetic datasets and on clinical data from ten patients with obstructive sleep apnea, using a previously developed two-dimensional SVD algorithm (SVDRI) as a reference. RESULTS: Across synthetic datasets, HO-SVD consistently outperformed SVDRI in all evaluation metrics. In clean conditions, HO-SVD improved the median signal-to-noise ratio (SNR) by 27 dB (131%) relative to the original signal. In datasets with mild motion artifacts and complex muscle interference, median SNR improvements of up to 19 dB (88%) were observed. The symmetric mean absolute error and mean frequency deviation were significantly lower for HO-SVD across all input SNRs (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Electrical Engineering, Eindhoven University of Technology, De Groene Loper 19, Eindhoven, 5612 AP, North Brabant, The Netherlands. Electronic address: g.m.gronska@tue.nl.
- Electrical Engineering, Eindhoven University of Technology, De Groene Loper 19, Eindhoven, 5612 AP, North Brabant, The Netherlands.
- Electrical Engineering, Eindhoven University of Technology, De Groene Loper 19, Eindhoven, 5612 AP, North Brabant, The Netherlands; Kempenhaeghe, Center for Sleep Medicine, Sterkselseweg 65, Heeze, 5591 VE, North Braban…
Förderung
- Technische Universiteit Eindhoven
Zitieren
APA
Grońska, G., Peri, E., Long, X., Overeem, S., van Dijk, J. P., & Mischi, M. (2026). Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2026.109559
Vancouver
Grońska G, Peri E, Long X, Overeem S, van Dijk JP, Mischi M. Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography. Computer Methods and Programs in Biomedicine. 2026. doi:10.1016/j.cmpb.2026.109559
BibTeX
@article{Groska2026,
author = {Grońska, Gabriela and Peri, Elisabetta and Long, Xi and Overeem, Sebastiaan and van Dijk, Johannes P and Mischi, Massimo},
title = {Multidimensional decomposition framework for electrocardiographic interference, noise and artifacts removal from diaphragmatic electromyography},
journal = {Computer Methods and Programs in Biomedicine},
year = {2026},
doi = {10.1016/j.cmpb.2026.109559}
}