EUVIMEDEUVIMED entdecken
Crossref

Novel explainable transformer model for automated attention-deficit hyperactivity disorder detection with EEG signals

Alexey Zavitaev, Ravinesh C Deo, Prabal D Barua, Aruna Devi, Jeffrey Soar, Rajendra Acharya

Computer Methods and Programs in Biomedicine · 2026-10 · 285 · 109499

DOI: 10.1016/j.cmpb.2026.109499 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026-10. Verfasst von Alexey Zavitaev und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Science, Engineering and Digital Technologies, University of Southern Queensland, Springfield Central, 4300, QLD, Australia. Hauptthemen laut MEDLINE: Attention Deficit Disorder with Hyperactivity, Electroencephalography, Signal Processing, Computer-Assisted. Die Arbeit nennt 57 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Recent developments in deep learning have increased our interest in its applications in medical fields, such as the automated detection of neurodevelopmental disorders from biological signals. Attention deficit hyperactivity disorder (ADHD) is a very common condition in this group, which typically begins in childhood and often persists into adulthood. Many automated methods use an electroencephalogram (EEG) for ADHD detection. EEG signals are known to be nonlinear, non-stationary and vary significantly among individuals. To deal with this, most detection methods use either complex hand-crafted features or deep learning. The latter approach may yield better results but lacks explainability, which is critical for adoption in medical practice. METHODS: In this paper, we propose an explainable transformer-based model for automatic ADHD detection from EEG signals. To establish trust, explainability and transparency in the artificial intelligence-based approach presented, we have used Local Interpretable Model-agnostic Explanations (LIME) to visualise the model's predictions, using clinical features of EEG signals - specifically, delta (1-3 Hz), theta (4-7 Hz) and beta (14-30 Hz) components. RESULTS: Our model has achieved an average accuracy of 96.2% with leave-one-out cross-validation on a public dataset. We showed that the explanations of the classification results are meaningful by linking them to clinically accepted ADHD markers. CONCLUSIONS: The results demonstrate the success of the proposed explainable transformer model for ADHD detection. We hope that the proposed model has the potential to increase trust in practicing clinicians so they explore its usage as an auxiliary tool for ADHD screening in healthcare settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Attention Deficit Disorder with HyperactivityElectroencephalographySignal Processing, Computer-AssistedHumansDeep LearningChildAlgorithmsDiagnosis, Computer-Assisted

Stichwörter der Autor:innen

ADHDArtificial IntelligenceAttention deficit hyperactivity disorderDeep learningEEGExplainable AITransformer

Autor:innen und Institutionen

  • School of Science, Engineering and Digital Technologies, University of Southern Queensland, Springfield Central, 4300, QLD, Australia.
  • School of Science, Engineering and Digital Technologies, University of Southern Queensland, Springfield Central, 4300, QLD, Australia. Electronic address: ravinesh.deo@unisq.edu.au.
  • School of Science, Engineering and Digital Technologies, University of Southern Queensland, Springfield Central, 4300, QLD, Australia; Cogninet AI, Surry Hills, 2010, NSW, Australia; Australian International Institute o…
  • Australian International Institute of Higher Education, Brisbane, 4000, QLD, Australia; School of Education, University of the Sunshine Coast, Petrie, 4502, QLD, Australia.
  • School of Business, University of Southern Queensland, Springfield Central, 4300, QLD, Australia.

Zitieren

APA

Zavitaev, A., Deo, R. C., Barua, P. D., Devi, A., Soar, J., & Acharya, R. (2026). Novel explainable transformer model for automated attention-deficit hyperactivity disorder detection with EEG signals. Computer Methods and Programs in Biomedicine, 285, 109499. https://doi.org/10.1016/j.cmpb.2026.109499

Vancouver

Zavitaev A, Deo RC, Barua PD, Devi A, Soar J, Acharya R. Novel explainable transformer model for automated attention-deficit hyperactivity disorder detection with EEG signals. Computer Methods and Programs in Biomedicine. 2026;285:109499. doi:10.1016/j.cmpb.2026.109499

BibTeX
@article{Zavitaev2026,
  author = {Zavitaev, Alexey and Deo, Ravinesh C and Barua, Prabal D and Devi, Aruna and Soar, Jeffrey and Acharya, Rajendra},
  title = {Novel explainable transformer model for automated attention-deficit hyperactivity disorder detection with EEG signals},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2026},
  volume = {285},
  pages = {109499},
  doi = {10.1016/j.cmpb.2026.109499}
}
Kostenlos starten →