EUVIMEDEUVIMED entdecken
Open Access

Clinically-aligned explainable AI for atrial fibrillation detection: A U-Net inspired multi-lead ECG analysis framework

Amirsajjad Taleban, Rodney Sparapani, Sharone Zlochiver, Qiang Lu, Michael E Widlansky, Jake Luo

Computer Methods and Programs in Biomedicine · 2026-10 · 285 · 109474

DOI: 10.1016/j.cmpb.2026.109474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026-10. Verfasst von Amirsajjad Taleban und 5 weiteren Autor:innen. Beteiligte Einrichtung: Health Informatics Program, Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI, USA. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electrocardiography, Diagnosis, Computer-Assisted. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, Advancing a Healthier Wisconsin Endowment.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVE: Deep learning offers high diagnostic accuracy but often lacks interpretability, hindering clinical adoption for Electrocardiogram (ECG) analysis. This study aims to develop a clinically interpretable, U-Net-inspired deep learning framework for Atrial Fibrillation (AFib) detection that elucidates model decision-making through morphological and rhythmic feature extraction. METHODS: We utilized a U-Net-inspired encoder-decoder architecture to analyze 12-lead ECGs as spatially structured inputs, capturing inter-lead relationships using the PTB-XL database. Model interpretability was assessed using layer-wise Gradient-weighted Class Activation Mapping (Grad-CAM) to visualize hierarchical feature focus. Additionally, we implemented RR interval variability assessment with heart rate stratification and group-specific threshold optimization to account for physiological variations. RESULTS: On PTB-XL-Improved labels, the model achieved an Area Under the Curve (AUC) of 99.15%, Sensitivity of 97.81%, Specificity of 95.63%, and Precision (PPV) of 95.72%. Performance on the original PTB-XL annotations reached an AUC of 99.78%. Grad-CAM analysis confirmed hierarchical feature extraction, correctly localizing QRS complexes in over 97.5% of cases and P-wave and rhythm irregularities in over 93.1% of cases. Independent RR-interval variability analysis achieved AUCs of 95.5% (slow heart rate), 93.2% (normal), and 91.3% (fast) across three clinically stratified heart rate groups. CONCLUSIONS: This framework successfully combines high diagnostic performance with transparent, clinically aligned visual explanations. The principal contribution is not accuracy alone, but the demonstration that layer-wise explanations can be aligned with the clinical ECG reading sequence, from QRS localization to P-wave morphology. External validation remains necessary before broader clinical generalization can be claimed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationElectrocardiographyDiagnosis, Computer-AssistedHumansSignal Processing, Computer-AssistedDeep LearningDatabases, FactualAlgorithmsSensitivity and SpecificityHeart RateArea Under Curve

Stichwörter der Autor:innen

Arrhythmia detectionConvolutional encoder–decoderElectrocardiographyGradient-weighted class activation mappingHeart rate variabilityInterpretable machine learningPTB-XL

Autor:innen und Institutionen

  • Health Informatics Program, Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI, USA.
  • Data Science Institute, Medical College of Wisconsin, Milwaukee, WI, USA.
  • Diagnostic Cardiology, Baxter International Inc., Greater Milwaukee, WI, USA.
  • Beijing Key Laboratory of Petroleum Data Mining, China University of Petroleum Beijing, Beijing, China.
  • Cardiovascular Research Center, Department of Medicine, Medical College of Wisconsin, Milwaukee, WI, USA.
  • Health Informatics Program, Zilber School of Public Health, University of Wisconsin-Milwaukee, Milwaukee, WI, USA. Electronic address: jakeluo@uwm.edu.

Förderung

  • NCATS NIH HHS
  • Advancing a Healthier Wisconsin Endowment

Zitieren

APA

Taleban, A., Sparapani, R., Zlochiver, S., Lu, Q., Widlansky, M. E., & Luo, J. (2026). Clinically-aligned explainable AI for atrial fibrillation detection: A U-Net inspired multi-lead ECG analysis framework. Computer Methods and Programs in Biomedicine, 285, 109474. https://doi.org/10.1016/j.cmpb.2026.109474

Vancouver

Taleban A, Sparapani R, Zlochiver S, Lu Q, Widlansky ME, Luo J. Clinically-aligned explainable AI for atrial fibrillation detection: A U-Net inspired multi-lead ECG analysis framework. Computer Methods and Programs in Biomedicine. 2026;285:109474. doi:10.1016/j.cmpb.2026.109474

BibTeX
@article{Taleban2026,
  author = {Taleban, Amirsajjad and Sparapani, Rodney and Zlochiver, Sharone and Lu, Qiang and Widlansky, Michael E and Luo, Jake},
  title = {Clinically-aligned explainable AI for atrial fibrillation detection: A U-Net inspired multi-lead ECG analysis framework},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2026},
  volume = {285},
  pages = {109474},
  doi = {10.1016/j.cmpb.2026.109474}
}
Kostenlos starten →