EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Refine XGBoost with SHAP explainability for non-invasive early detection of diabetic kidney disease: Estimated cardiac output as a potential indicator

Ngoc Minh To, Quoc Cuong Ngo, Barbara Polus, Minh Ngoc Dinh, Ahsan Khandoker, Anish Menon, Dinesh Kumar

Computer Methods and Programs in Biomedicine · 2026

DOI: 10.1016/j.cmpb.2025.109122 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2026. Verfasst von Ngoc Minh To und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, RMIT University, Melbourne, Australia; School of Science, Engineering and Technology, RMIT University, HCMC, Viet Nam. Hauptthemen laut MEDLINE: Diabetic Nephropathies, Cardiac Output. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bangladesh University of Health Sciences, Medical Research Future Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Moderately increased (micro) albuminuria serves as a critical early indicator of Diabetic Kidney Disease (DKD). However, traditional screening methods that rely on laboratory-based analyses face significant challenges in enabling timely and continuous monitoring. This study addresses these limitations by introducing a non-invasive approach for albuminuria risk detection, allowing real-time estimation of mild albuminuria increases using vital signs and body measurements. METHODS: We developed a non-invasive model for albuminuria risk detection using vital signs and body measurements. Data were drawn from the NHANES cohort (USA) and a Bangladeshi cohort of people with diabetes (PwD). Feature selection identified four non-laboratory predictors - estimated cardiac output (eCO), body mass index, waist circumference, and diabetes duration - as the most informative inputs. The proposed models were benchmarked against baseline machine learning approaches and existing methods developed over the past decade, with model interpretability assessed via SHapely Additive exPlanation (SHAP) contributions. RESULTS: Our best model, an XGBoost classifier, achieved an AUC of 0.75 [0.67-0.84], an accuracy of 0.70, and a macro F1 score of 0.68, outperforming other non-invasive risk scores (0.58) and machine learning baselines. Validation against an external reference risk score confirmed superior precision-recall balance for both positive (microalbuminuria) and negative classes. CONCLUSION: This study demonstrates that a fine-tuned, non-invasive XGBoost model using simple clinical measures can support albuminuria monitoring and early DKD detection without laboratory tests. While the selected predictors may not represent the definitive or optimal feature set, their strong performance highlights the potential of leveraging easily obtainable, clinically relevant measures. In particular, the contribution of eCO underscores a promising direction for exploring heart-kidney-metabolism interactions in DKD risk assessment. Together, these findings highlight a scalable, non-invasive tool for resource-limited settings, an interpretable framework for clinical trust, and a pathway to refining feature sets for both accuracy and biological insight.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetic NephropathiesCardiac OutputHumansEarly DiagnosisMaleFemaleAlbuminuriaMiddle AgedMachine LearningBangladeshAgedNutrition SurveysAdultAlgorithmsBoosting Machine Learning Algorithms

Stichwörter der Autor:innen

AlbuminuriaDKDDiabetic kidney diseaseEstimated cardiac output (eCO)Machine learningNon-invasive medical screening

Autor:innen und Institutionen

  • School of Engineering, RMIT University, Melbourne, Australia; School of Science, Engineering and Technology, RMIT University, HCMC, Viet Nam.
  • School of Engineering, RMIT University, Melbourne, Australia.
  • School of Science, Engineering and Technology, RMIT University, HCMC, Viet Nam.
  • Healthcare Engineering Innovation Group, Department of Biomedical Engineering and Biotechnology, Khalifa University of Science and Technology, Abu Dhabi, United Arab Emirates.
  • Centre for Health Services Research, The University of Queensland, Brisbane, Australia; Princess Alexandra Hospital, Metro South Health, Brisbane, Australia.
  • School of Engineering, RMIT University, Melbourne, Australia. Electronic address: dinesh.kumar@rmit.edu.au.

Förderung

  • Bangladesh University of Health Sciences
  • Medical Research Future Fund

Zitieren

APA

To, N. M., Ngo, Q. C., Polus, B., Dinh, M. N., Khandoker, A., Menon, A., & Kumar, D. (2026). Refine XGBoost with SHAP explainability for non-invasive early detection of diabetic kidney disease: Estimated cardiac output as a potential indicator. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2025.109122

Vancouver

To NM, Ngo QC, Polus B, Dinh MN, Khandoker A, Menon A, et al. Refine XGBoost with SHAP explainability for non-invasive early detection of diabetic kidney disease: Estimated cardiac output as a potential indicator. Computer Methods and Programs in Biomedicine. 2026. doi:10.1016/j.cmpb.2025.109122

BibTeX
@article{To2026,
  author = {To, Ngoc Minh and Ngo, Quoc Cuong and Polus, Barbara and Dinh, Minh Ngoc and Khandoker, Ahsan and Menon, Anish and Kumar, Dinesh},
  title = {Refine XGBoost with SHAP explainability for non-invasive early detection of diabetic kidney disease: Estimated cardiac output as a potential indicator},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2026},
  doi = {10.1016/j.cmpb.2025.109122}
}
Kostenlos starten →