EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of CTA-based closed-loop coronary artery flow simulations against intravascular Doppler velocity and pressure measurements

Anahita Seresti, Alison L Marsden, Andrew M Kahn, Ryan R Reeves, Ehtisham Mahmud, Belal Al Khiami, Lawrence Ang, M Owais Khan

Computer Methods and Programs in Biomedicine · 2025-08 · 268 · 108868

DOI: 10.1016/j.cmpb.2025.108868 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025-08. Verfasst von Anahita Seresti und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Coronary Vessels, Computed Tomography Angiography, Coronary Angiography, Coronary Circulation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: The modeling assumptions involved in computational fluid dynamics (CFD) simulations of coronary arteries using coronary computed angiography (CTA) have not been thoroughly validated. These modeling assumptions can lead to uncertainties in simulated velocities and pressure, and consequently, other hemodynamic markers, such as wall shear stresses. In this study, we validated a state-of-the-art coronary CTA-CFD simulation strategy against intravascular Doppler velocity and pressure measurements. METHODS: 3D coronary models were reconstructed using coronary CTA in 13 patients. Intravascular Doppler velocities and pressures were obtained in 18 arteries over 120 ± 55 cardiac cycles to validate CTA-CFD simulations. A lumped parameter network (LPN) was tuned to capture each patient's heart and distal coronary circulation, and coupled to the CFD solver. For each patient, Murray's Law coefficient was varied from 2.0 to 3.0 in increments of 0.2. The simulated velocities and pressures were compared to intravascular measurements. RESULTS: The correlation between intravascular and CTA-CFD parameters showed no statistically significant correlation for velocity (r=-0.13 and p = 0.60), while both flow rates (r = 0.77, p < 0.01) and pressures (r = 0.88, p < 0.01) demonstrated strong correlation and statistical significance. When considering the intra-patient cycle-to-cycle variabilities in invasive measurements, velocity in 11 of 18 and pressures in 7 of 18 coronary arteries were within one standard deviation of intravascular measurement variability. CONCLUSION: CTA-CFD simulations showed statistically significant correlations for intravascular flows and pressures, whereas no meaningful correlation was observed for velocity. These findings highlight the influence of measurement variability and modeling assumptions. Future studies should consider the inherent uncertainties in CTA-CFD, especially when estimating absolute hemodynamic parameters such as velocity and pressure, and aim to refine boundary conditions and validation strategies to improve accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary VesselsComputed Tomography AngiographyCoronary AngiographyCoronary CirculationHumansComputer SimulationBlood Flow VelocityMaleMiddle AgedFemaleHydrodynamicsHemodynamicsAgedModels, CardiovascularReproducibility of Results

Stichwörter der Autor:innen

Computational fluid dynamicsComputed tomography angiographyCoronary blood flow

Autor:innen und Institutionen

  • Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada.
  • Department of Pediatrics, Stanford University, Stanford, CA, USA; Department of Bioengineering, Stanford University, Stanford, CA, USA; Institute for Computational and Mathematical Engineering, Stanford University, Stan…
  • Division of Cardiovascular Medicine, University of California San Diego, La Jolla, CA, USA.
  • Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada. Electronic address: owaiskhan@torontomu.ca.

Förderung

  • NHLBI NIH HHS
  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Seresti, A., Marsden, A. L., Kahn, A. M., Reeves, R. R., Mahmud, E., Khiami, B. A., Ang, L., & Khan, M. O. (2025). Validation of CTA-based closed-loop coronary artery flow simulations against intravascular Doppler velocity and pressure measurements. Computer Methods and Programs in Biomedicine, 268, 108868. https://doi.org/10.1016/j.cmpb.2025.108868

Vancouver

Seresti A, Marsden AL, Kahn AM, Reeves RR, Mahmud E, Khiami BA, et al. Validation of CTA-based closed-loop coronary artery flow simulations against intravascular Doppler velocity and pressure measurements. Computer Methods and Programs in Biomedicine. 2025;268:108868. doi:10.1016/j.cmpb.2025.108868

BibTeX
@article{Seresti2025,
  author = {Seresti, Anahita and Marsden, Alison L and Kahn, Andrew M and Reeves, Ryan R and Mahmud, Ehtisham and Khiami, Belal Al and Ang, Lawrence and Khan, M Owais},
  title = {Validation of CTA-based closed-loop coronary artery flow simulations against intravascular Doppler velocity and pressure measurements},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2025},
  volume = {268},
  pages = {108868},
  doi = {10.1016/j.cmpb.2025.108868}
}