EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Development of patient-specific apparent blood viscosity predictive models for computational fluid dynamics analysis of intracranial aneurysms with machine learning approaches

Takashi Suzuki, Hiroyuki Takao, Tomoaki Suzuki, Soichiro Fujimura, Shunsuke Hataoka, Tomonobu Kodama, Ken Aoki, Toshihiro Ishibashi, Makoto Yamamoto, Hideki Yamamoto, Yuichi Murayama

Computer Methods and Programs in Biomedicine · 2025

DOI: 10.1016/j.cmpb.2025.108831 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025. Verfasst von Takashi Suzuki und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Division of Innovation…. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Blood Viscosity, Machine Learning, Hydrodynamics. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: A model to predict patient-specific apparent viscosity as a computational condition in computational fluid dynamics (CFD) analysis, which is used in research on intracranial aneurysms, is important. The purpose of this study was to develop a model to predict patient-specific apparent viscosity from clinical blood test results. METHODS: The data were from 15 patients with intracranial aneurysms in whom blood viscosity and density were measured and blood tests were performed on the same day. The dataset was divided into two, a training dataset and a test dataset at a ratio of 4:1. The training dataset was used in constructing regression models with shear rate and 12 blood test items (the flexible model) or hematocrit (the simple model) as input, and the measured apparent viscosity as output. CFD analysis was implemented with and without coil geometries, and the viscosity models were evaluated. RESULTS: The root mean squared error (RMSE) of viscosity predicted with the flexible model and the simple model was 0.136 mPa·s and 0.226 mPa·s, respectively. The RMSE of time-averaged and space-averaged velocity and time-averaged and space-averaged wall shear stress computed in CFD analysis were

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial AneurysmBlood ViscosityMachine LearningHydrodynamicsHumansMaleFemaleMiddle AgedComputer SimulationAdultAgedHematocrit

Stichwörter der Autor:innen

Artificial intelligenceComputational fluid dynamicsHemodynamicsIntracranial aneurysmMachine learningRheologyViscosity

Autor:innen und Institutionen

  • Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Division of Innovation for Medical Information Technology, The Jikei University School of Me…
  • Department of Neurosurgery, Brain Research Institute, Niigata University, 754 Ichibancho Asahimachidori Chuo-ku, Niigata-shi, Niigata 951-8510, Japan.
  • Division of Innovation for Medical Information Technology, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan; Department of Mechanical Engineering, Tokyo University of Sci…
  • Department of Neurosurgery, The Jikei University School of Medicine, 3-25-8 Nishi-shinbashi, Minato-ku, Tokyo 105-8461, Japan.
  • Department of Neurological Surgery, Nihon University School of Medicine, 1-6 Kanda Surugadai, Chiyoda-ku, Tokyo 101-8309, Japan.
  • Department of Mechanical Engineering, Tokyo University of Science, 6-3-1 Niijuku Katsushika-ku, Tokyo 125-8585, Japan.

Zitieren

APA

Suzuki, T., Takao, H., Suzuki, T., Fujimura, S., Hataoka, S., Kodama, T., Aoki, K., Ishibashi, T., Yamamoto, M., Yamamoto, H., & Murayama, Y. (2025). Development of patient-specific apparent blood viscosity predictive models for computational fluid dynamics analysis of intracranial aneurysms with machine learning approaches. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2025.108831

Vancouver

Suzuki T, Takao H, Suzuki T, Fujimura S, Hataoka S, Kodama T, et al. Development of patient-specific apparent blood viscosity predictive models for computational fluid dynamics analysis of intracranial aneurysms with machine learning approaches. Computer Methods and Programs in Biomedicine. 2025. doi:10.1016/j.cmpb.2025.108831

BibTeX
@article{Suzuki2025,
  author = {Suzuki, Takashi and Takao, Hiroyuki and Suzuki, Tomoaki and Fujimura, Soichiro and Hataoka, Shunsuke and Kodama, Tomonobu and Aoki, Ken and Ishibashi, Toshihiro and Yamamoto, Makoto and Yamamoto, Hideki and Murayama, Yuichi},
  title = {Development of patient-specific apparent blood viscosity predictive models for computational fluid dynamics analysis of intracranial aneurysms with machine learning approaches},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2025},
  doi = {10.1016/j.cmpb.2025.108831}
}