EUVIMEDEUVIMED entdecken
Crossref

Severity grading of hypertensive retinopathy using hybrid deep learning architecture

Supriya Suman, Anil Kumar Tiwari, Shreya Sachan, Kuldeep Singh, Seema Meena, Sakshi Kumar

Computer Methods and Programs in Biomedicine · 2025-04 · 261 · 108585

DOI: 10.1016/j.cmpb.2025.108585 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025-04. Verfasst von Supriya Suman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Research Division: Smart Healthcare, Indian Institute of Technology, Jodhpur, 342030, Rajasthan, India. Electronic address: suman.4…. Hauptthemen laut MEDLINE: Deep Learning, Hypertensive Retinopathy, Diagnosis, Computer-Assisted. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 62 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: Hypertensive Retinopathy (HR) is a retinal manifestation resulting from persistently elevated blood pressure. Severity grading of HR is essential for patient risk stratification, effective management, progression monitoring, timely intervention, and minimizing the risk of vision impairment. Computer-aided diagnosis and artificial intelligence (AI) systems play vital roles in the diagnosis and grading of HR. Over the years, very limited research has been conducted for the grading of HR. Nevertheless, there are no publicly available datasets for HR grading. Moreover, one of the key challenges observed is high-class imbalance. METHODS: To address these issues, in this paper, we develop "HRSG: Expert-Annotated Hypertensive Retinopathy Severity Grading" dataset, classifying HR severity into four distinct classes: normal, mild, moderate, and severe. Further, to enhance the grading performance on limited datasets, this paper introduces a novel hybrid architecture that combines the strengths of pretrained ResNet-50 via transfer learning, and a modified Vision Transformer (ViT) architecture enhanced with a combination of global self-attention and locality self-attention mechanisms. The locality self-attention addresses the common issue of a lack of inductive bias in ViT architecture. This architecture effectively captures both local and global contextual information, resulting in a robust and resilient classification model. To overcome class imbalance, Decouple Representation and Classifier (DRC) - based training approach is proposed. This method improves the model's ability to learn effective features while preserving the original dataset's distribution, leading to better diagnostic accuracy. RESULTS: Performance evaluation results show the competence of the proposed method in accurately grading the severity of HR. The proposed method achieved an average accuracy of 0.9688, sensitivity of 0.9435, specificity of 0.9766, F1-score of 0.9442, and precision of 0.9474. The comparative results indicate that the proposed method outperforms existing HR methods, state-of-the-art CNN models, and baseline pretrained ViT models. Additionally, we compared our method with a CNNViT model, which combines a shallow CNN architecture with 3 convolution blocks consisting of a convolution layer, a batch normalization layer, a max pooling layer, and lightweight ViT architecture, due to limited datasets. In comparison with the CNNViT, the proposed method achieved superior performance, demonstrating its effectiveness. CONCLUSION: The experimental results demonstrate the efficacy of the proposed method in accurately grading HR severity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningHypertensive RetinopathyDiagnosis, Computer-AssistedHumansSeverity of Illness IndexAlgorithmsArtificial Intelligence

Stichwörter der Autor:innen

Class Imbalance HandlingComputer-aided DiagnosisDeep LearningFundus Image AnalysisHypertensive Retinopathy Severity GradingRepresentation LearningVision Transformer

Autor:innen und Institutionen

  • Interdisciplinary Research Division: Smart Healthcare, Indian Institute of Technology, Jodhpur, 342030, Rajasthan, India. Electronic address: suman.4@iitj.ac.in.
  • Department of Electrical Engineering, Indian Institute of Technology Jodhpur, 342030, Rajasthan, India.
  • Department of Pediatrics, All India Institute of Medical Sciences, Jodhpur, 342005, Rajasthan, India.
  • Department of Ophthalmology, All India Institute of Medical Sciences, Jodhpur, 342005, Rajasthan, India.
  • Regional Institute of Ophthalmology, Indira Gandhi Institute of Medical Sciences, Patna, 800025, Bihar, India.

Zitieren

APA

Suman, S., Tiwari, A. K., Sachan, S., Singh, K., Meena, S., & Kumar, S. (2025). Severity grading of hypertensive retinopathy using hybrid deep learning architecture. Computer Methods and Programs in Biomedicine, 261, 108585. https://doi.org/10.1016/j.cmpb.2025.108585

Vancouver

Suman S, Tiwari AK, Sachan S, Singh K, Meena S, Kumar S. Severity grading of hypertensive retinopathy using hybrid deep learning architecture. Computer Methods and Programs in Biomedicine. 2025;261:108585. doi:10.1016/j.cmpb.2025.108585

BibTeX
@article{Suman2025,
  author = {Suman, Supriya and Tiwari, Anil Kumar and Sachan, Shreya and Singh, Kuldeep and Meena, Seema and Kumar, Sakshi},
  title = {Severity grading of hypertensive retinopathy using hybrid deep learning architecture},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2025},
  volume = {261},
  pages = {108585},
  doi = {10.1016/j.cmpb.2025.108585}
}
Kostenlos starten →