A computational workflow for modeling complex patient-specific coronary stenting cases
Computer Methods and Programs in Biomedicine · 2025-02 · 259 · 108527
DOI: 10.1016/j.cmpb.2024.108527 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2025-02. Verfasst von Luca Antonini und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biological Structures Mechanics (LaBS) - Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Mil…. Hauptthemen laut MEDLINE: Stents, Coronary Vessels, Computer Simulation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: In the era of in silico clinical trials, it is of paramount importance to guarantee simulation reliability. In the field of coronary stenting, there is a need to couple validated stent models with credible digital twins of the arteries, whose mechanical behavior is commonly simplified to guarantee a balance between simulation complexity and computational time, namely usability. To this aim, the current work proposed a phenomenological approach suitable for the mechanical description of patient-specific coronary arteries undergoing coronary stenting in complex cases, e.g. bifurcations, exhibiting overstretching due to procedural choices. METHODS: Pre- and post-operative images were used to prepare four vessel models and validate the outcome of multi-step structural stenting simulations in terms of recovered lumen area. Arteries were modeled improving a previous strategy by the authors, namely accounting for different mechanical properties in the media and adventitia layer, with an assigned hyperelastic response with a softening at higher strains to simulate the damage due to overstretching. Plaque components, which were identified from patient images, were classified into lipidic, calcified, and generic, and associated with different properties. RESULTS: The simulation results demonstrated a good match with the clinical outcome of all the stenting procedures, with errors lower than 15 % in terms of recovered lumen area. This proved the reliability of the proposed simulation framework improving the performances of the previous model, making it usable for interpreting also situations where the artery underwent overstretching. CONCLUSIONS: The proposed approach allowed to account for the in vivo conditions and have good performance when aiming at describing quantities such as lumen reopening and the presence of malapposed struts following stent deployment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of Biological Structures Mechanics (LaBS) - Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy; Parametric Des…
- Laboratory of Biological Structures Mechanics (LaBS) - Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milano, Italy. Electronic add…
- Department of Biomedical Research Institute-FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; 2nd Department of Cardiology, University Hospital of Ioannina, 45110 Ioannina, Greece. Electronic address: g.kara…
- Department of Biomedical Research Institute-FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; 2nd Department of Cardiology, University Hospital of Ioannina, 45110 Ioannina, Greece. Electronic address: ansake…
- Department of Biomedical Research Institute-FORTH, University Campus of Ioannina, 45110 Ioannina, Greece; 2nd Department of Cardiology, University Hospital of Ioannina, 45110 Ioannina, Greece. Electronic address: fotiad…
- Department of Civil and Environmental Engineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy. Electronic address: lorenza.petrini@polimi.it.
Zitieren
APA
Antonini, L., Poletti, G., Karanasiou, G. S., Sakellarios, A., Fotiadis, D. I., Petrini, L., Pennati, G., & Berti, F. (2025). A computational workflow for modeling complex patient-specific coronary stenting cases. Computer Methods and Programs in Biomedicine, 259, 108527. https://doi.org/10.1016/j.cmpb.2024.108527
Vancouver
Antonini L, Poletti G, Karanasiou GS, Sakellarios A, Fotiadis DI, Petrini L, et al. A computational workflow for modeling complex patient-specific coronary stenting cases. Computer Methods and Programs in Biomedicine. 2025;259:108527. doi:10.1016/j.cmpb.2024.108527
BibTeX
@article{Antonini2025,
author = {Antonini, Luca and Poletti, Gianluca and Karanasiou, Georgia S and Sakellarios, Antonis and Fotiadis, Dimitrios I and Petrini, Lorenza and Pennati, Giancarlo and Berti, Francesca},
title = {A computational workflow for modeling complex patient-specific coronary stenting cases},
journal = {Computer Methods and Programs in Biomedicine},
year = {2025},
volume = {259},
pages = {108527},
doi = {10.1016/j.cmpb.2024.108527}
}
EUVIMED