EUVIMEDEUVIMED entdecken
Crossref

OrthoCalc: The six degrees of freedom measurement workflow of rotational and displacement changes for maxilla positioning evaluation

Yao Gao, Yifei Gu, Jeroen Van Dessel, Heinz-Theo Lübbers, Lei Tian, Constantinus Politis, Michel Bila, Robin Willaert, Xiaojun Chen, Yi Sun

Computer Methods and Programs in Biomedicine · 2024

DOI: 10.1016/j.cmpb.2024.108083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024. Verfasst von Yao Gao und 9 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Belgium. Hauptthemen laut MEDLINE: Orthognathic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: China Scholarship Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: This study is undertaken to establish the accuracy and reliability of OrthoCalc, a 3D application designed for the evaluation of maxillary positioning. METHODS: We registered target virtual planned models, maxillary models from pre-operative and post-operative CT scans, and post-operative intra-oral scans to a common reference system, allowing for digital evaluation. To assess rotational changes, we introduced a novel measurement method based on virtual cuboid models. Displacement errors were calculated based on proposed registration matrices. We also compared OrthoCalc to established commercial medical software as a benchmark. RESULTS: Statistical significance calculated showed no significant differences between OrthoCalc and commercial software. the biggest error of 0.04 degree in rotation change was found in the yaw. A maximum displacement change of 0.75 mm was found in the X direction. CONCLUSIONS: Our study validates OrthoCalc as a precise and reliable tool for assessing maxillary position changes with six degrees of freedom in orthognathic surgery, endorsing its clinical utility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthognathic Surgical ProceduresSurgery, Computer-AssistedMaxillaReproducibility of ResultsWorkflowSoftwareImaging, Three-Dimensional

Stichwörter der Autor:innen

Computer-aided surgeryMaxillaOrthognathic surgeryPlastic surgeryPost-operative evaluation

Autor:innen und Institutionen

  • The Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Belgium.
  • The Fourth Affiliated Hospital of Soochow University, PR China.
  • Clinic for Cranio-Maxillofacial Surgery, University Hospital of Zurich, Frauenklinikstrasse 24, Zurich CH-8091, Switzerland; Harvard Medical School, Brigham and Women's Hospital, Surgical Planning Laboratory, Francis St…
  • State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Diseases and Shaanxi Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, School of Stomat…
  • Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, PR China; Institute…
  • The Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Belgium. Electronic address: yi.sun@uzleuven.be.

Förderung

  • China Scholarship Council

Zitieren

APA

Gao, Y., Gu, Y., Dessel, J. V., Lübbers, H. T., Tian, L., Politis, C., Bila, M., Willaert, R., Chen, X., & Sun, Y. (2024). OrthoCalc: The six degrees of freedom measurement workflow of rotational and displacement changes for maxilla positioning evaluation. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2024.108083

Vancouver

Gao Y, Gu Y, Dessel JV, Lübbers HT, Tian L, Politis C, et al. OrthoCalc: The six degrees of freedom measurement workflow of rotational and displacement changes for maxilla positioning evaluation. Computer Methods and Programs in Biomedicine. 2024. doi:10.1016/j.cmpb.2024.108083

BibTeX
@article{Gao2024,
  author = {Gao, Yao and Gu, Yifei and Dessel, Jeroen Van and Lübbers, Heinz-Theo and Tian, Lei and Politis, Constantinus and Bila, Michel and Willaert, Robin and Chen, Xiaojun and Sun, Yi},
  title = {OrthoCalc: The six degrees of freedom measurement workflow of rotational and displacement changes for maxilla positioning evaluation},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2024},
  doi = {10.1016/j.cmpb.2024.108083}
}
Kostenlos starten →