CDRNet: Cascaded dense residual network for grayscale and pseudocolor medical image fusion
Computer Methods and Programs in Biomedicine · 2023-06 · 234 · 107506
DOI: 10.1016/j.cmpb.2023.107506 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023-06. Verfasst von Jun Fu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Engineering, Zunyi Normal University, Zunyi, Guizhou, 563006, China. Electronic address: jeffsonfu@126.com. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Multimodal Imaging. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 63 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Multimodal medical fusion images have been widely used in clinical medicine, computer-aided diagnosis and other fields. However, the existing multimodal medical image fusion algorithms generally have shortcomings such as complex calculations, blurred details and poor adaptability. To solve this problem, we propose a cascaded dense residual network and use it for grayscale and pseudocolor medical image fusion. METHODS: The cascaded dense residual network uses a multiscale dense network and a residual network as the basic network architecture, and a multilevel converged network is obtained through cascade. The cascaded dense residual network contains 3 networks, the first-level network inputs two images with different modalities to obtain a fused Image 1, the second-level network uses fused Image 1 as the input image to obtain fused Image 2 and the third-level network uses fused Image 2 as the input image to obtain fused Image 3. The multimodal medical image is trained through each level of the network, and the output fusion image is enhanced step-by-step. RESULTS: As the number of networks increases, the fusion image becomes increasingly clearer. Through numerous fusion experiments, the fused images of the proposed algorithm have higher edge strength, richer details, and better performance in the objective indicators than the reference algorithms. CONCLUSION: Compared with the reference algorithms, the proposed algorithm has better original information, higher edge strength, richer details and an improvement of the four objective SF, AG, MZ and EN indicator metrics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Information Engineering, Zunyi Normal University, Zunyi, Guizhou, 563006, China. Electronic address: jeffsonfu@126.com.
- Nanchang Institute of Technology, Nanchang, Jiangxi, 330044, China.
- School of Information Engineering, Zunyi Normal University, Zunyi, Guizhou, 563006, China.
- School of Science, East China Jiaotong University, Nanchang, Jiangxi, 330013, China.
Zitieren
APA
Fu, J., He, B., Yang, J., Liu, J., Ouyang, A., & Wang, Y. (2023). CDRNet: Cascaded dense residual network for grayscale and pseudocolor medical image fusion. Computer Methods and Programs in Biomedicine, 234, 107506. https://doi.org/10.1016/j.cmpb.2023.107506
Vancouver
Fu J, He B, Yang J, Liu J, Ouyang A, Wang Y. CDRNet: Cascaded dense residual network for grayscale and pseudocolor medical image fusion. Computer Methods and Programs in Biomedicine. 2023;234:107506. doi:10.1016/j.cmpb.2023.107506
BibTeX
@article{Fu2023,
author = {Fu, Jun and He, Baiqing and Yang, Jie and Liu, Jianpeng and Ouyang, Aijia and Wang, Ya},
title = {CDRNet: Cascaded dense residual network for grayscale and pseudocolor medical image fusion},
journal = {Computer Methods and Programs in Biomedicine},
year = {2023},
volume = {234},
pages = {107506},
doi = {10.1016/j.cmpb.2023.107506}
}
EUVIMED