EUVIMEDEUVIMED entdecken
Crossref

A high-fidelity geometric multiscale hemodynamic model for predicting myocardial ischemia

Jincheng Liu, Bao Li, Yanping Zhang, Liyuan Zhang, Suqin Huang, Hao Sun, Jian Liu, Xi Zhao, Mingzi Zhang, Wenxin Wang, Youjun Liu

Computer Methods and Programs in Biomedicine · 2023

DOI: 10.1016/j.cmpb.2023.107476 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023. Verfasst von Jincheng Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China. Hauptthemen laut MEDLINE: Coronary Stenosis, Fractional Flow Reserve, Myocardial, Coronary Artery Disease, Myocardial Ischemia. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: Coronary computed tomography angiography (CCTA) derived fractional flow reserve (CT-FFR) requires a maximal hyperemic state to be modeled by assuming the total coronary resistance decreased to a constant 0.24 of that under the resting state. However, this assumption neglects the vasodilator capacity of individual patients. Herein, we proposed a high-fidelity geometric multiscale model (HFMM) to characterize coronary pressure and flow under the resting state, seeking to better predict myocardial ischemia by using CCTA-derived instantaneous wave-free ratio (CT-iFR). METHODS: Fifty-seven patients (62 lesions) who had undergone CCTA and were then referred to invasive FFR were prospectively enrolled. The coronary microcirculation resistance hemodynamic model (RHM) under the resting condition was established on a patient-specific basis. Coupled with a closed-loop geometric multiscale model (CGM) of their individual coronary circulations, the HFMM model was established to non-invasively derive the CT-iFR from CCTA images. RESULTS: With the invasive FFR being the reference standard, accuracy of the obtained CT-iFR in identifying myocardial ischemia was greater than those of the CCTA and non-invasively derived CT-FFR (90.32% vs. 79.03% vs. 84.3%). The overall computational time of CT-iFR was 61 ± 6 min, faster than that of the CT-FFR (8 h). The sensitivity, specificity, positive predictive value, and negative predictive value of the CT-iFR in discriminating an invasive FFR > 0.8 were 78% (95% CI: 40-97%), 92% (95% CI: 82-98%), 64% (95% CI: 39-83%), and 96% (95% CI:88-99%), respectively. CONCLUSIONS: A high-fidelity geometric multiscale hemodynamic model was developed for rapid and accurate estimation of CT-iFR. Compared with CT-FFR, CT-iFR is of less computational cost and enables assessment of tandem lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary StenosisFractional Flow Reserve, MyocardialCoronary Artery DiseaseMyocardial IschemiaHumansCoronary AngiographyHemodynamicsPredictive Value of TestsSeverity of Illness Index

Stichwörter der Autor:innen

Computational fluid dynamics (CFD)Coronary artery diseaseCoronary pre-arterioles compensationInstantaneous wave-free ratio (iFR)

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China.
  • Department of Cardiology, Peking University People's Hospital, Beijing, China.
  • Central Research Institute, United Imaging Healthcare, Shanghai, China.
  • Macquarie Medical School, Faculty of Medicine, Health, and Human Sciences, Macquarie University, Sydney, Australia.
  • Philips Healthcare China, Shanghai, China.
  • Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, China. Electronic address: lyjlma@bjut.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, J., Li, B., Zhang, Y., Zhang, L., Huang, S., Sun, H., Liu, J., Zhao, X., Zhang, M., Wang, W., & Liu, Y. (2023). A high-fidelity geometric multiscale hemodynamic model for predicting myocardial ischemia. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2023.107476

Vancouver

Liu J, Li B, Zhang Y, Zhang L, Huang S, Sun H, et al. A high-fidelity geometric multiscale hemodynamic model for predicting myocardial ischemia. Computer Methods and Programs in Biomedicine. 2023. doi:10.1016/j.cmpb.2023.107476

BibTeX
@article{Liu2023,
  author = {Liu, Jincheng and Li, Bao and Zhang, Yanping and Zhang, Liyuan and Huang, Suqin and Sun, Hao and Liu, Jian and Zhao, Xi and Zhang, Mingzi and Wang, Wenxin and Liu, Youjun},
  title = {A high-fidelity geometric multiscale hemodynamic model for predicting myocardial ischemia},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2023},
  doi = {10.1016/j.cmpb.2023.107476}
}
Kostenlos starten →