Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response
Computer Methods and Programs in Biomedicine · 2023-03 · 230 · 107342
DOI: 10.1016/j.cmpb.2023.107342 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023-03. Verfasst von Ricardo Belda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Universidad Carlos III de Madrid, Avda. de la Universidad 30, Leganés, 28911, Madrid, Spain; Institute of Mecha…. Hauptthemen laut MEDLINE: Tissue Scaffolds, Bone and Bones. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 41 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVE: Design of bone scaffolds requires a combination of material and geometry to fulfil requirements of mechanical properties, porosity and pore size. Triply Periodic Minimal Surface (TPMS) structures have gained attention due to their similarities to cancellous bone. In this work, we aim at exploring relationships between morphometry and mechanical properties for TPMS configurations. METHODS: Eight TPMS structures are defined considering six porosity levels and their morphometry is characterized. The stiffness matrix of each structure is assessed and related to morphometry through a statistical analysis. RESULTS: An orthotropic mechanical behavior has been derived from the numerical homogenization. Properties decay exponentially for decreasing volume fraction. Through volume fraction variation, TPMS mechanical properties can be selected to match bone properties in a range of 0.2% to 70% of the bulk material properties. CONCLUSIONS: The comparison between cancellous bone and TPMS morphometry, considering a unit cell size of 1.5 mm, reveals that the configurations analyzed in this work match the requirements of volume fraction, mean thickness and pore size. However, the TPMS studied in this work differ from cancellous bone anisotropy. The results in this paper provide a framework to select the proper TPMS configuration and its geometry for patient-specific applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Universidad Carlos III de Madrid, Avda. de la Universidad 30, Leganés, 28911, Madrid, Spain; Institute of Mechanical and Biomechanical Engineering - I2MB, Department of Mechanical E…
- Institute of Mechanical and Biomechanical Engineering - I2MB, Department of Mechanical Engineering and Materials, Universitat Politècnica de València, Camino de Vera, Valencia 46022, Spain.
- Department of Mechanical Engineering, Universidad Carlos III de Madrid, Avda. de la Universidad 30, Leganés, 28911, Madrid, Spain.
Zitieren
APA
Belda, R., Megías, R., Marco, M., Vercher-Martínez, A., & Giner, E. (2023). Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response. Computer Methods and Programs in Biomedicine, 230, 107342. https://doi.org/10.1016/j.cmpb.2023.107342
Vancouver
Belda R, Megías R, Marco M, Vercher-Martínez A, Giner E. Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response. Computer Methods and Programs in Biomedicine. 2023;230:107342. doi:10.1016/j.cmpb.2023.107342
BibTeX
@article{Belda2023,
author = {Belda, Ricardo and Megías, Raquel and Marco, Miguel and Vercher-Martínez, Ana and Giner, Eugenio},
title = {Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response},
journal = {Computer Methods and Programs in Biomedicine},
year = {2023},
volume = {230},
pages = {107342},
doi = {10.1016/j.cmpb.2023.107342}
}
EUVIMED