Endotracheal aspirate as an alternative to bronchoalveolar lavage fluid for the diagnosis of Pneumocystis pneumonia by real-time polymerase chain reaction

Sang-Ho Choi, Sang-Bum Hong, Jin Won Huh, Heungsup Sung, Kyung-Hyun Do, Sang-Oh Lee, Chae-Man Lim, Younsuck Koh

Clinical Microbiology and Infection · 2025-11 · 31 (11) · 1914-1917

DOI: 10.1016/j.cmi.2025.07.031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Microbiology and Infection, 2025-11. Verfasst von Sang-Ho Choi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Pneumonia, Pneumocystis, Bronchoalveolar Lavage Fluid, Real-Time Polymerase Chain Reaction, Pneumocystis carinii. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The purpose of this study was to evaluate the diagnostic performance of an endotracheal aspirate (ETA) real-time polymerase chain reaction (RT-PCR) assay for the diagnosis of Pneumocystis jirovecii pneumonia in intensive care unit (ICU) patients with suspected pneumonia. METHODS: We conducted a retrospective analysis of a prospective cohort in a 28-bed medical ICU. Adult patients who underwent both ETA and bronchoalveolar lavage (BAL) sampling for P. jirovecii real-time PCR within 48 hours between October 2018 and December 2024 were included. Diagnostic performance metrics of the ETA RT-PCR assay were calculated using BAL RT-PCR results as the reference standard (cycle threshold [Ct] ≤40). The concordance of Ct values between ETA and BAL samples was assessed using Pearson correlation. RESULTS: Among 249 included patients, 69 (27.7%) were positive for P. jirovecii by BAL RT-PCR. The ETA RT-PCR showed a sensitivity of 85.5% (95% confidence interval [CI]: 75.0-92.8%), a specificity of 92.8% (95% CI: 88.0-96.1%), an accuracy of 90.7% (95% CI: 86.4-94.0%), a positive likelihood ratio of 11.84, and a negative likelihood ratio of 0.16. Ct values between ETA and BAL samples were strongly correlated (r = 0.78, p < 0.001). Discordant results were observed in 23 patients (9.2%), with false-positive ETA samples showing significantly higher Ct values (median: 34.6; interquartile range [IQR]: 33.1-35.4) than true positives (median: 26.4; IQR: 24.2-31.0; p < 0.01). DISCUSSION: ETA RT-PCR for P. jirovecii demonstrates high diagnostic concordance with BAL fluid RT-PCR in ICU patients and may serve as a minimally invasive alternative. However, elevated Ct values in ETA samples warrant further confirmatory testing due to possible colonization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pneumonia, PneumocystisBronchoalveolar Lavage FluidReal-Time Polymerase Chain ReactionPneumocystis cariniiTracheaHumansMaleFemaleRetrospective StudiesMiddle AgedSensitivity and SpecificityAgedIntensive Care UnitsProspective StudiesAdultAged, 80 and over

Stichwörter der Autor:innen

Bronchoalveolar lavageIntensive care unitPneumocystis jiroveciiPneumoniaReal-time PCR

Autor:innen und Institutionen

  • Department of Infectious Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. Electronic address: yskoh@amc.seoul.kr.

Zitieren

APA

Choi, S. H., Hong, S. B., Huh, J. W., Sung, H., Do, K. H., Lee, S. O., Lim, C. M., & Koh, Y. (2025). Endotracheal aspirate as an alternative to bronchoalveolar lavage fluid for the diagnosis of Pneumocystis pneumonia by real-time polymerase chain reaction. Clinical Microbiology and Infection, 31(11), 1914-1917. https://doi.org/10.1016/j.cmi.2025.07.031

Vancouver

Choi SH, Hong SB, Huh JW, Sung H, Do KH, Lee SO, et al. Endotracheal aspirate as an alternative to bronchoalveolar lavage fluid for the diagnosis of Pneumocystis pneumonia by real-time polymerase chain reaction. Clinical Microbiology and Infection. 2025;31(11):1914-1917. doi:10.1016/j.cmi.2025.07.031

BibTeX
@article{Choi2025,
  author = {Choi, Sang-Ho and Hong, Sang-Bum and Huh, Jin Won and Sung, Heungsup and Do, Kyung-Hyun and Lee, Sang-Oh and Lim, Chae-Man and Koh, Younsuck},
  title = {Endotracheal aspirate as an alternative to bronchoalveolar lavage fluid for the diagnosis of Pneumocystis pneumonia by real-time polymerase chain reaction},
  journal = {Clinical Microbiology and Infection},
  year = {2025},
  volume = {31},
  number = {11},
  pages = {1914--1917},
  doi = {10.1016/j.cmi.2025.07.031}
}
Kostenlos starten →