Evaluation of cryptococcal antigen lateral flow assay in human immunodeficiency virus–negative cryptococcosis: a diagnostic accuracy study
Clinical Microbiology and Infection · 2025-10 · 31 (10) · 1720-1725
DOI: 10.1016/j.cmi.2025.06.021 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Clinical Microbiology and Infection, 2025-10. Verfasst von Siguang Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China. Hauptthemen laut MEDLINE: Antigens, Fungal, Cryptococcosis, Meningitis, Cryptococcal, Cryptococcus. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangdong Provincial Natural Science Foundation.
Abstract (Originalsprache)
OBJECTIVES: This study aims to evaluate the diagnostic accuracy of cryptococcal antigen lateral flow assay (CrAg LFA) in HIV-negative populations. METHODS: The CrAg LFA results of 2918 paired serum and cerebrospinal fluid (CSF) from 1459 HIV-negative inpatients (including 354 cryptococcosis and 1105 non-cryptococcosis) who underwent both serum and CSF CrAg LFA tests were retrospectively collected. Time-series analysis of sensitivity values for CrAg LFA from 2019 to 2024 was performed using linear interpolation and Gaussian smoothing. The diagnostic capability of serum CrAg LFA for predicting cryptococcal meningitis (CM) was assessed by logistic regression. Spearman's rank correlation analysed the relationship between serum and CSF CrAg LFA titres. RESULTS: The sensitivity of serum CrAg LFA test for diagnosing cryptococcosis was 97.7% (95% CI: 96.2-99.3%), with a specificity of 99.1% (95% CI: 98.5-99.7%), positive predictive value of 97.2% (95% CI: 95.5-98.9%), and negative predictive value of 99.3% (95% CI: 98.8-99.8%). False-positive serum CrAg LFA were identified in ten patients without cryptococcosis. The sensitivity, specificity, positive predictive value, and negative predictive value of CSF CrAg LFA test for the diagnosis of CM were 100% (95% CI: 100-100%), 99.9% (95% CI: 99.7-100%), 99.7% (95% CI: 99.1-100%), and 100% (95% CI: 100-100%), respectively. One case with a false-positive CSF CrAg LFA was identified. The receiver operating characteristic curve demonstrated an area under the curve of 0.96 (95% CI: 0.959-0.963) for CM in serum CrAg LFA-positive patients with neurological symptoms. DISCUSSION: This study highlights the high sensitivity and specificity of the CrAg LFA test in HIV-negative patients. This test can be used as an effective tool for the first-line rapid diagnosis of cryptococcosis in HIV-negative populations, regardless of the determination of the CrAg LFA titre.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neurology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China.
- School of Data Science, The Chinese University of Hong Kong, Shenzhen, People's Republic of China.
- Department of Neurology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China. Electronic address: jiangy9@mail.sysu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Guangdong Provincial Natural Science Foundation
Zitieren
APA
Wang, S., Chen, X., Shi, J., Dai, K., Pan, Q., Liu, J., Xu, X., Peng, F., & Jiang, Y. (2025). Evaluation of cryptococcal antigen lateral flow assay in human immunodeficiency virus–negative cryptococcosis: a diagnostic accuracy study. Clinical Microbiology and Infection, 31(10), 1720-1725. https://doi.org/10.1016/j.cmi.2025.06.021
Vancouver
Wang S, Chen X, Shi J, Dai K, Pan Q, Liu J, et al. Evaluation of cryptococcal antigen lateral flow assay in human immunodeficiency virus–negative cryptococcosis: a diagnostic accuracy study. Clinical Microbiology and Infection. 2025;31(10):1720-1725. doi:10.1016/j.cmi.2025.06.021
BibTeX
@article{Wang2025,
author = {Wang, Siguang and Chen, Xi and Shi, Jiasheng and Dai, Kai and Pan, Qiyu and Liu, Jia and Xu, Xiaofeng and Peng, Fuhua and Jiang, Ying},
title = {Evaluation of cryptococcal antigen lateral flow assay in human immunodeficiency virus–negative cryptococcosis: a diagnostic accuracy study},
journal = {Clinical Microbiology and Infection},
year = {2025},
volume = {31},
number = {10},
pages = {1720--1725},
doi = {10.1016/j.cmi.2025.06.021}
}
EUVIMED