Use of High-Frequency Ventilation in the Newborn: Jet, Oscillator, Flow Interruption or Percussion?
Clinics in Perinatology · 2026-06 · 53 (2) · 215-231
DOI: 10.1016/j.clp.2026.02.004 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Clinics in Perinatology, 2026-06. Verfasst von Noelia González-Pacheco und 3 weiteren Autor:innen. Beteiligte Einrichtung: Neonatology Division, Hospital General Universitario Gregorio Marañón, C/ÓDonnell 48-50, 28009, Madrid, Spain; Department of Paediatrics, Complutense…. Hauptthemen laut MEDLINE: High-Frequency Ventilation, Respiratory Distress Syndrome, Newborn, High-Frequency Jet Ventilation, Ventilator-Induced Lung Injury. Die Arbeit nennt 59 Literaturangaben.
Abstract (Originalsprache)
In the sentence beginning with "High-frequency ventilation (HFV) maintains functional residual capacity and minimizes ventilator-induced lung injury by delivering subdead-space tidal volumes at supraphysiologic frequencies. Its performance depends on airway size and lung mechanics, making it effective in preterm infants with low compliance. HFV modalities include high-frequency jet ventilation, delivering rapid gas pulses with passive exhalation to improve gas exchange and support lung stabilization, especially in air-leak syndromes; high-frequency oscillatory ventilation, providing bidirectional oscillations at constant mean airway pressure, enabling alveolar recruitment while limiting volutrauma and atelectrauma, with volume-guarantee strategies enhancing stability and protection; and less common percussive or flow-interruption ventilation with limited neonatal evidence…" please link the citations to the references as appropriate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neonatology Division, Hospital General Universitario Gregorio Marañón, C/ÓDonnell 48-50, 28009, Madrid, Spain; Department of Paediatrics, Complutense University of Madrid, Spain. Electronic address: noelia.gonzalez.pach…
- Division of Paediatric and Neonatal Critical Care, APHP-Paris Saclay University Hospitals, "A. Beclere" Medical Center, 157 Rue de la Porte de Trivaux, 92140, Clamart, Paris, France.
- Neonatology Division, Hospital General Universitario Gregorio Marañón, C/ÓDonnell 48-50, 28009, Madrid, Spain; Department of Paediatrics, Complutense University of Madrid, Spain.
Zitieren
APA
González-Pacheco, N., Manganelli, N. P., De Luca, D., & Sánchez-Luna, M. (2026). Use of High-Frequency Ventilation in the Newborn: Jet, Oscillator, Flow Interruption or Percussion?. Clinics in Perinatology, 53(2), 215-231. https://doi.org/10.1016/j.clp.2026.02.004
Vancouver
González-Pacheco N, Manganelli NP, De Luca D, Sánchez-Luna M. Use of High-Frequency Ventilation in the Newborn: Jet, Oscillator, Flow Interruption or Percussion?. Clinics in Perinatology. 2026;53(2):215-231. doi:10.1016/j.clp.2026.02.004
BibTeX
@article{GonzlezPacheco2026,
author = {González-Pacheco, Noelia and Manganelli, Nunzia Pia and De Luca, Daniele and Sánchez-Luna, Manuel},
title = {Use of High-Frequency Ventilation in the Newborn: Jet, Oscillator, Flow Interruption or Percussion?},
journal = {Clinics in Perinatology},
year = {2026},
volume = {53},
number = {2},
pages = {215--231},
doi = {10.1016/j.clp.2026.02.004}
}
EUVIMED