Does a Magnetic Resonance–Only Pathway Impact Dosimetric and Acute Clinical Outcomes in Prostate Stereotactic Ablative Body Radiotherapy?
Clinical Oncology · 2026-10 · 104356
DOI: 10.1016/j.clon.2026.104356 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oncology, 2026-10. Verfasst von J J Wyatt und 9 weiteren Autor:innen. Beteiligte Einrichtung: Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Ne…. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
AIMS: This study aimed to compare prostate target and organs at risk (OAR) volumes, doses, and acute toxicity scores for patients treated with prostate stereotactic ablative body radiotherapy (SABR) using magnetic resonance (MR)-only or MR registered with computed tomography (MR-CT) pathways. MATERIALS AND METHODS: A total of 486 patients prescribed 36.25 Gy in five fractions were included. Patients were treated using a. MR-CT (January-October 2024, n = 262) or MR-only (October 2024-August 2025, n = 222) pathway. Unfavourable risk patients (36% MR-only, 37% MR-CT) received additional hormone therapy. Sixty-five percent of MR-only patients and 76% of MR-CT patients attended an acute toxicity assessment two weeks post treatment using Common Toxicity Criteria. Prostate, bladder, penile bulb, and rectum volumes and dose constraints were compared between the two pathways using the Mann-Whitney U-test. The proportion of patients reporting acute toxicity of grade ≥1, ≥2, and ≥3 were compared. RESULTS: Median MR-only prostate volumes were 38-9+10cm3 value to third quartile, -value to first quartile, compared to MR-CT volumes of 40-10+11cm3, a 4% reduction (P = .07). For unfavourable risk patients only, the reduction was 10%, 30-7+7 cm3 (MR-only) and 33-7+7 cm3 (MR-CT, P = .04). For both favourable and unfavourable risk patients, the penile bulb mean dose was 52% lower, 2.2 Gy (MR-only) compared to 4.6 Gy (MR-CT, P < .001). There was a reduction of -20.3% (95% confidence interval: -37.4%, -3.2%) in acute grade ≥1 and -21.7% (-39.4%, -3.7%) in grade ≥2 sexual toxicities in the MR-only cohort, although the sexual toxicity response rates were low. CONCLUSION: MR-only prostate SABR significantly reduced penile bulb doses and may have reduced target volumes and acute sexual toxicity while enabling improved patient experience and departmental efficiency. These findings need to be validated in larger patient cohorts with longer-term follow-up.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Newcastle University, Newcastle, UK. Electronic address: jonathanwyatt@n…
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK.
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK; Translational and Clinical Research Institute, Newcastle University, Newcastle, UK.
Zitieren
APA
Wyatt, J. J., Eassom, A., West, S., Brooks-Pearson, R. L., Richmond, N., Ormston, B., Chandler, R., Frew, J., Jiang, X., & Pearson, R. A. (2026). Does a Magnetic Resonance–Only Pathway Impact Dosimetric and Acute Clinical Outcomes in Prostate Stereotactic Ablative Body Radiotherapy?. Clinical Oncology, 104356. https://doi.org/10.1016/j.clon.2026.104356
Vancouver
Wyatt JJ, Eassom A, West S, Brooks-Pearson RL, Richmond N, Ormston B, et al. Does a Magnetic Resonance–Only Pathway Impact Dosimetric and Acute Clinical Outcomes in Prostate Stereotactic Ablative Body Radiotherapy?. Clinical Oncology. 2026:104356. doi:10.1016/j.clon.2026.104356
BibTeX
@article{Wyatt2026,
author = {Wyatt, J J and Eassom, A and West, S and Brooks-Pearson, R L and Richmond, N and Ormston, B and Chandler, R and Frew, J and Jiang, X and Pearson, R A},
title = {Does a Magnetic Resonance–Only Pathway Impact Dosimetric and Acute Clinical Outcomes in Prostate Stereotactic Ablative Body Radiotherapy?},
journal = {Clinical Oncology},
year = {2026},
pages = {104356},
doi = {10.1016/j.clon.2026.104356}
}
EUVIMED