EUVIMEDEUVIMED entdecken
Vergleichsstudie

Reliability and accuracy of rectus femoris muscle measurements by dietitians using ultrasound, compared to sonographers

Erin Russell, Dalena Nguyen, Sophie Page, Angel Lee, Mary Anne Silvers, Ed Saxby, Darcy Holt, Suong Le, Peter Coombs

Clinical Nutrition ESPEN · 2026-06 · 73 · 103111

DOI: 10.1016/j.clnesp.2026.103111 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Nutrition ESPEN, 2026-06. Verfasst von Erin Russell und 8 weiteren Autor:innen. Beteiligte Einrichtung: Nutrition and Dietetics, Monash Health, Australia. Electronic address: Erin.russell@monashhealth.org. Hauptthemen laut MEDLINE: Nutritionists, Quadriceps Muscle. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND & AIMS Point-of-care (POCUS) ultrasound measurement of the rectus femoris is a useful tool for diagnosing myopenia. Current literature indicates Dietitians are completing these measurements in research settings with high methodological heterogeneity. We aim to determine the reliability and accuracy of dietitians using ultrasound to measure rectus femoris muscle, after rapid training, compared to sonographers. METHODS A training program was designed by sonographers and completed by two study dietitians in 12 hours. In this prospective cohort study, patients with a diagnosis of chronic liver disease (CLD) were recruited from the outpatient clinics and heathy participants (HP) were opportunistically recruited on-site. Two dietitians and two sonographers marked the ultrasound picture. Thickness, width, circumference and surface area were measured. Inter-rater reliability was presented as an intra class correlation (ICC, 95%CI) for reliability, and Bland-Altman assessment for bias and accuracy. RESULTS 42 HP and 18 patients with CLD were recruited. ICC across the four raters, four ultrasound measurements and across BMI and sex ranged from minimum 0.73 (good) to 0.96 (excellent) in accuracy. For rectus femoris thickness, ICC was similar across both groups: 0.88 (95% CI: 0.82-0.93) in HP and CLD patients 0.86 (95%CI: 0.71-0.94). Bland-Altman for thickness systematic error of differences between dietitians and sonographers was not statistically significant (0.032cm, p =0.554). CONCLUSION With a standardised training protocol, ultrasound-naïve dietitians achieved both reliable and accurate ultrasound measurements when compared to sonographers in both healthy participants and patients with CLD. Future research should determine the scalability and generalisability of this training protocol.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NutritionistsQuadriceps MuscleHumansUltrasonographyReproducibility of ResultsFemaleMaleProspective StudiesMiddle AgedAgedAdultObserver Variation

Stichwörter der Autor:innen

DietitianSarcopeniaUltrasound

Autor:innen und Institutionen

  • Nutrition and Dietetics, Monash Health, Australia. Electronic address: Erin.russell@monashhealth.org.
  • Ultrasound Department, Monash Imaging, Monash Health, Australia.
  • Nutrition and Dietetics, Monash Health, Australia.
  • Department of Gastroenterology, Monash Health, Australia.
  • Department of Gastroenterology, Monash Health, Australia; Clinical Nutrition and Metabolism Unit, Monash Health, Australia; Monash University, Faculty of Medicine, Nursing and Health Sciences, Australia.
  • Department of Gastroenterology, Monash Health, Australia; Monash University, Faculty of Medicine, Nursing and Health Sciences, Australia.

Zitieren

APA

Russell, E., Nguyen, D., Page, S., Lee, A., Silvers, M. A., Saxby, E., Holt, D., Le, S., & Coombs, P. (2026). Reliability and accuracy of rectus femoris muscle measurements by dietitians using ultrasound, compared to sonographers. Clinical Nutrition ESPEN, 73, 103111. https://doi.org/10.1016/j.clnesp.2026.103111

Vancouver

Russell E, Nguyen D, Page S, Lee A, Silvers MA, Saxby E, et al. Reliability and accuracy of rectus femoris muscle measurements by dietitians using ultrasound, compared to sonographers. Clinical Nutrition ESPEN. 2026;73:103111. doi:10.1016/j.clnesp.2026.103111

BibTeX
@article{Russell2026,
  author = {Russell, Erin and Nguyen, Dalena and Page, Sophie and Lee, Angel and Silvers, Mary Anne and Saxby, Ed and Holt, Darcy and Le, Suong and Coombs, Peter},
  title = {Reliability and accuracy of rectus femoris muscle measurements by dietitians using ultrasound, compared to sonographers},
  journal = {Clinical Nutrition ESPEN},
  year = {2026},
  volume = {73},
  pages = {103111},
  doi = {10.1016/j.clnesp.2026.103111}
}
Kostenlos starten →