EUVIMEDEUVIMED entdecken
Open Access

Long-term stability of the alcohol consumption biomarker phosphatidylethanol in erythrocytes at −80 °C

Hans-Åke Lakso, Anna Wuolikainen, Anneli Sundkvist, Ingegerd Johansson, Stefan L Marklund

Clinical Mass Spectrometry · 2019-01 · 11 · 37-41

DOI: 10.1016/j.clinms.2018.12.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Mass Spectrometry, 2019-01. Verfasst von Hans-Åke Lakso und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biosciences, Clinical Chemistry, Umeå University, Umeå, Sweden. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Västerbotten Läns Landsting, Vetenskapsrådet.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Phosphatidylethanol (PEth) is a recently introduced biomarker with high specificity, high sensitivity, and response correlating with alcohol consumption. It has the potential to be a valuable biomarker in population studies on the health effects of alcohol, however its stability in long-term stored blood is not known. We used LC-MS/MS to assess the stability of PEth-16:0/18:1 in blood samples (packed erythrocytes) that were stored between 1 and 19 years at -80 °C in a biobank from a large population survey. The participants answered a life-style questionnaire that included questions on alcohol consumption. For analysis, we selected blood samples from seven homogenous ethanol consumption cohorts collected at intervals from 1997 to 2015. Despite the narrow stated alcohol consumption range, 10-15 g/day, there were large differences in PEth values between individuals in the cohorts, from below the limit of detection of 0.005 µmol/L to 1.40 µmol/L. The median was 0.08 µmol/L. Neither generalized linear modeling, nor principal component analysis revealed a statistically significant association between time of storage and PEth levels. The PEth results indicate that the participants had, on average, under-reported their alcohol consumption several-fold. The findings suggest that PEth in blood has a sufficient long-term stability for use as an alcohol biomarker in prospective case-control studies. Analysis of blood stored in biobanks could significantly improve the validity of assessments exploring the health effects of alcohol.

Schlagwörter

Stichwörter der Autor:innen

BiobankCE, collision energyCXP, collision exit potentialEthanolGLM, generalized linear modellingHealth effectsLOD, limit of detectionLOQ, limit of quantificationPCA, principal component analysisPEth, phosphatidylethanolPopulation studiesStabilityVIP, Västerbotten Intervention Programme

Autor:innen und Institutionen

  • Department of Medical Biosciences, Clinical Chemistry, Umeå University, Umeå, Sweden.
  • Department of Chemistry, Umeå University, Umeå, Sweden.
  • Department of Radiation Sciences, Oncology, Umeå University, Umeå, Sweden.
  • Department of Odontology, Umeå University, Umeå, Sweden.

Förderung

  • Västerbotten Läns Landsting
  • Vetenskapsrådet

Zitieren

APA

Lakso, H. Å., Wuolikainen, A., Sundkvist, A., Johansson, I., & Marklund, S. L. (2019). Long-term stability of the alcohol consumption biomarker phosphatidylethanol in erythrocytes at −80 °C. Clinical Mass Spectrometry, 11, 37-41. https://doi.org/10.1016/j.clinms.2018.12.002

Vancouver

Lakso HÅ, Wuolikainen A, Sundkvist A, Johansson I, Marklund SL. Long-term stability of the alcohol consumption biomarker phosphatidylethanol in erythrocytes at −80 °C. Clinical Mass Spectrometry. 2019;11:37-41. doi:10.1016/j.clinms.2018.12.002

BibTeX
@article{Lakso2019,
  author = {Lakso, Hans-Åke and Wuolikainen, Anna and Sundkvist, Anneli and Johansson, Ingegerd and Marklund, Stefan L},
  title = {Long-term stability of the alcohol consumption biomarker phosphatidylethanol in erythrocytes at −80 °C},
  journal = {Clinical Mass Spectrometry},
  year = {2019},
  volume = {11},
  pages = {37--41},
  doi = {10.1016/j.clinms.2018.12.002}
}
Kostenlos starten →