EUVIMEDEUVIMED entdecken
Open Access

Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers

Irene van den Broek, Qin Fu, Stuart Kushon, Michael P Kowalski, Kevin Millis, Andrew Percy, Ronald J Holewinski, Vidya Venkatraman, Jennifer E Van Eyk

Clinical Mass Spectrometry · 2017

DOI: 10.1016/j.clinms.2017.08.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Mass Spectrometry, 2017. Verfasst von Irene van den Broek und 8 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Clinical Biosystems Research Institute, The Heart Institute, Cedars Sinai Medical Center, Los Angeles, CA, USA. Die Arbeit wurde bisher 57-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Volumetric absorptive micro sampling (VAMS™) allows accurate sampling of 10 µL of blood from a minimally invasive finger prick and could enable remote personalized health monitoring. Moreover, VAMS overcomes effects from hematocrit and sample heterogeneity associated with dried blood spots (DBS). We describe the first application of VAMS with the Mitra® microsampling device for the quantification of protein biomarkers using an automated, high-throughput sample preparation method coupled with mass spectrometric (MS) detection. The analytical performance of the developed workflow was evaluated for 10 peptides from six clinically relevant proteins: apolipoproteins A-I, B, C-I, C-III, E, and human serum albumin (HSA). Extraction recovery from blood with three different levels of hematocrit varied between 100% and 111% for all proteins. Within-day and total assay reproducibility (i.e., 5 replicates on 5 days) ranged between 3.2-10.4% and 3.4-12.6%, respectively. In addition, after 22 weeks of storage of the Mitra microsampling devices at -80 °C, all peptide responses were within ±15% deviation from the initial response. Application to data-independent acquisition (DIA) MS further demonstrated the potential for broad applicability and the general robustness of the automated workflow by reproducible detection of 1661 peptides from 423 proteins (average 15.7%CV (n = 3) in peptide abundance), correlating to peptide abundances in corresponding plasma (R = 0.8383). In conclusion, we have developed an automated workflow for efficient extraction, digestion, and MS analysis of a variety of proteins in a fixed small volume of dried blood (i.e., 10 µL). This robust and high-throughput workflow will create manifold opportunities for the application of remote, personalized disease biomarker monitoring.

Schlagwörter

Stichwörter der Autor:innen

ApolipoproteinsData-independent acquisitionDried bloodMass spectrometryRemote monitoringSelected reaction monitoring

Autor:innen und Institutionen

  • Advanced Clinical Biosystems Research Institute, The Heart Institute, Cedars Sinai Medical Center, Los Angeles, CA, USA.
  • Neoteryx®, Torrance, CA, USA.
  • Beckman Coulter Life Sciences, Indianapolis, IN, USA.
  • Cambridge Isotope Laboratories, Tewksbury, MA, USA.

Förderung

  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

van den Broek, I., Fu, Q., Kushon, S., Kowalski, M. P., Millis, K., Percy, A., Holewinski, R. J., Venkatraman, V., & Van Eyk, J. E. (2017). Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers. Clinical Mass Spectrometry. https://doi.org/10.1016/j.clinms.2017.08.004

Vancouver

van den Broek I, Fu Q, Kushon S, Kowalski MP, Millis K, Percy A, et al. Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers. Clinical Mass Spectrometry. 2017. doi:10.1016/j.clinms.2017.08.004

BibTeX
@article{vandenBroek2017,
  author = {van den Broek, Irene and Fu, Qin and Kushon, Stuart and Kowalski, Michael P and Millis, Kevin and Percy, Andrew and Holewinski, Ronald J and Venkatraman, Vidya and Van Eyk, Jennifer E},
  title = {Application of volumetric absorptive microsampling for robust, high-throughput mass spectrometric quantification of circulating protein biomarkers},
  journal = {Clinical Mass Spectrometry},
  year = {2017},
  doi = {10.1016/j.clinms.2017.08.004}
}
Kostenlos starten →