EUVIMEDEUVIMED entdecken
Crossref

Reducing Clip Migration in Mammographic-Guided Vacuum Assisted Biopsy With Direct Insertion of the UltraCor Twirl Clip Marker: A Quality Improvement Project

Sabrina Omar Bintalib, Shiu Suwn Yeo, Hin Yeung Marcus Loh, Awesh Shamrao Gambre, Ling Fung Amanda Liew

Clinical Breast Cancer · 2026-07 · 26 (7) · 46-55

DOI: 10.1016/j.clbc.2026.05.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Breast Cancer, 2026-07. Verfasst von Sabrina Omar Bintalib und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Oncologic Imaging, National Cancer Centre Singapore, Singapore. Hauptthemen laut MEDLINE: Surgical Instruments, Breast Neoplasms, Mammography, Quality Improvement. Die Arbeit nennt 19 Literaturangaben. Gefördert von: National Cancer Centre of Singapore.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Clip migration is frequently observed in mammographic-guided vacuum-assisted biopsies (VAB) and is associated with greater tissue excision and re-excision rates. Our institutional baseline clip migration rate was 23.5%, with one-third of cases yielding borderline or malignant histology potentially requiring localisation. Studies on modifiable factors affecting clip migration have yielded mixed results. MATERIALS AND METHODS: We implemented a direct puncture technique using the UltraCor Twirl clip to reduce clip migration in mammographic-guided VAB, targeting below 15%. Data were collected from September 2021 to July 2023 across two PDSA cycles: PDSA 1 introduced UltraCor Twirl clip deployment; PDSA 2 incorporated education and stock supply securing. Primary outcome measured was clip migration rate. Additional factors were analysed using Chi Square test and multivariable analysis, tracked via run-chart. RESULTS: 790 procedures were analysed. Clip migration rate dropped from 23.5% to 21.0% after PDSA 1 and to 13.5% after PDSA 2, sustained over 6 months. UltraCor Twirl clip was the only statistically significant modifiable factor associated with reduced clip migration at 7.9%, compared to 20.7% for bare metal clips and 24.0% for clips with bioabsorbable coating (p = 0.000233). Fatty breast was associated with higher migration (p = 0.015) but is non-modifiable. CONCLUSION: Deployment of the UltraCor Twirl clip via direct puncture, as part of a bundled intervention, was associated with significantly reduced clip migration rates. While the relative contributions of clip design, operator education, and system maturation cannot be fully isolated, the intervention is practical, sustainable, and potentially scalable. Multi-centre validation is needed to establish broader applicability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgical InstrumentsBreast NeoplasmsMammographyQuality ImprovementImage-Guided BiopsyForeign-Body MigrationHumansFemaleMiddle AgedBreastVacuum

Stichwörter der Autor:innen

Accordion effectBreast biopsyMammographic guidanceMarker clipStereotactic biopsy

Autor:innen und Institutionen

  • Division of Oncologic Imaging, National Cancer Centre Singapore, Singapore.
  • Division of Oncologic Imaging, National Cancer Centre Singapore, Singapore; SingHealth Duke-NUS Disease Centres (SDDCs) Breast Centre, Singapore. Electronic address: liewlingfung@yahoo.co.uk.

Förderung

  • National Cancer Centre of Singapore

Zitieren

APA

Bintalib, S. O., Yeo, S. S., Loh, H. Y. M., Gambre, A. S., & Liew, L. F. A. (2026). Reducing Clip Migration in Mammographic-Guided Vacuum Assisted Biopsy With Direct Insertion of the UltraCor Twirl Clip Marker: A Quality Improvement Project. Clinical Breast Cancer, 26(7), 46-55. https://doi.org/10.1016/j.clbc.2026.05.007

Vancouver

Bintalib SO, Yeo SS, Loh HYM, Gambre AS, Liew LFA. Reducing Clip Migration in Mammographic-Guided Vacuum Assisted Biopsy With Direct Insertion of the UltraCor Twirl Clip Marker: A Quality Improvement Project. Clinical Breast Cancer. 2026;26(7):46-55. doi:10.1016/j.clbc.2026.05.007

BibTeX
@article{Bintalib2026,
  author = {Bintalib, Sabrina Omar and Yeo, Shiu Suwn and Loh, Hin Yeung Marcus and Gambre, Awesh Shamrao and Liew, Ling Fung Amanda},
  title = {Reducing Clip Migration in Mammographic-Guided Vacuum Assisted Biopsy With Direct Insertion of the UltraCor Twirl Clip Marker: A Quality Improvement Project},
  journal = {Clinical Breast Cancer},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {46--55},
  doi = {10.1016/j.clbc.2026.05.007}
}
Kostenlos starten →