EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Multifocal contact lenses for preoperative simulation of enhanced monofocal and extended depth of focus intraocular lenses using adaptive optics

Luca Giacopinelli, Silvia Carrasco-Rojo, Inas Baoud Ould Haddi, César Albarrán-Diego, Nuria Garzón, María García-Montero

Contact Lens and Anterior Eye · 2026

DOI: 10.1016/j.clae.2026.102665 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2026. Verfasst von Luca Giacopinelli und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry and Vision, Complutense University of Madrid, Madrid Spain. Hauptthemen laut MEDLINE: Presbyopia, Multifocal Intraocular Lenses, Depth Perception, Lens Implantation, Intraocular. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: State Agency of Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate whether multifocal contact lenses (CLs) can serve as preoperative simulators of postoperative vision with enhanced monofocal and extended depth of focus (EDOF) intraocular lenses (IOLs), using the SimVis Gekko™ adaptive-optics visual simulator. METHODS: Twenty-four presbyopic subjects (mean age 54.9 ± 5.0 years; range 46-63) underwent monocular simulation of two daily disposable multifocal CLs (1-Day Acuvue® Moist Multifocal, medium addition; and Biotrue® ONEday for Presbyopia, high addition) and two IOLs (Tecnis® Eyhance™, enhanced monofocal; and LuxSmart™, EDOF) using the SimVis Gekko™ under photopic conditions and a fixed 3 mm pupil aperture. Monocular defocus curves were obtained from -3.00 to +1.00 D in 0.50 D steps. Area under the curve (AUC), negative-defocus cutoff at the 0.2 logMAR threshold, and defocus slopes from linear mixed-effects models were compared across lens conditions for both raw and offset corrected datasets. RESULTS: Both CLs exhibited a systematic -0.50 D myopic offset relative to the IOL simulations, consistent with their center-near design. After applying a +0.50 D vergence correction, AUC values were comparable across all four designs (p = 0.18). At the 0.2 logMAR threshold, LuxSmart showed the widest functional range (cutoff -2.38 ± 0.66 D) and Biotrue the narrowest (-1.69 ± 0.53 D). Mixed-effects modeling indicated equivalent defocus slopes between 1-Day Acuvue Moist and Tecnis Eyhance after vergence alignment (p = 0.894), while LuxSmart showed greater defocus tolerance and Biotrue degraded significantly faster (p = 0.005). CONCLUSIONS: Once the intrinsic -0.50 D myopic offset is compensated, the 1-Day Acuvue Moist Multifocal closely replicates the through-focus visual performance of the Tecnis Eyhance IOL, supporting its use as a practical preoperative simulator for patients being considered for enhanced monofocal implantation. Multifocal CLs combined with adaptive optics simulation may assist surgeons in tailoring IOL selection and improve shared decision-making before cataract surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PresbyopiaMultifocal Intraocular LensesDepth PerceptionLens Implantation, IntraocularLenses, IntraocularHumansMiddle AgedFemaleMaleProsthesis DesignVisual AcuityRefraction, OcularComputer SimulationPreoperative Care

Autor:innen und Institutionen

  • Department of Optometry and Vision, Complutense University of Madrid, Madrid Spain.
  • Department of Optometry and Vision, Complutense University of Madrid, Madrid Spain. Electronic address: ibaoud@ucm.es.
  • Department of Optics, Optometry and Vision Science, Universitat de València, Doctor Moliner 50, 46100 Burjassot, Spain.

Förderung

  • State Agency of Research

Zitieren

APA

Giacopinelli, L., Carrasco-Rojo, S., Ould Haddi, I. B., Albarrán-Diego, C., Garzón, N., & García-Montero, M. (2026). Multifocal contact lenses for preoperative simulation of enhanced monofocal and extended depth of focus intraocular lenses using adaptive optics. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2026.102665

Vancouver

Giacopinelli L, Carrasco-Rojo S, Ould Haddi IB, Albarrán-Diego C, Garzón N, García-Montero M. Multifocal contact lenses for preoperative simulation of enhanced monofocal and extended depth of focus intraocular lenses using adaptive optics. Contact Lens and Anterior Eye. 2026. doi:10.1016/j.clae.2026.102665

BibTeX
@article{Giacopinelli2026,
  author = {Giacopinelli, Luca and Carrasco-Rojo, Silvia and Ould Haddi, Inas Baoud and Albarrán-Diego, César and Garzón, Nuria and García-Montero, María},
  title = {Multifocal contact lenses for preoperative simulation of enhanced monofocal and extended depth of focus intraocular lenses using adaptive optics},
  journal = {Contact Lens and Anterior Eye},
  year = {2026},
  doi = {10.1016/j.clae.2026.102665}
}
Kostenlos starten →