Effect of a thermo-mechanical action device on symptoms, signs and tear lipid profile in patients with evaporative dry eye disease
Contact Lens and Anterior Eye · 2026
DOI: 10.1016/j.clae.2026.102656 ↗Kurz gefasst
Kontrollierte klinische Studie in der Zeitschrift Contact Lens and Anterior Eye, 2026. Verfasst von Bhagyashree Rajesh Rawal und 5 weiteren Autor:innen. Beteiligte Einrichtung: Optometry and Vision Sciences Research Group, Aston University, Birmingham, United Kingdom. Electronic address: 210322284@aston.ac.uk. Hauptthemen laut MEDLINE: Tears, Dry Eye Syndromes, Lipids, Hyperthermia, Induced. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: To evaluate the effect of a thermo-mechanical action device on symptoms, signs and overall tear lipid profile in patients with evaporative dry eye. METHODS: A prospective, controlled, open-label research was conducted, involving participants with an Ocular Surface Disease Index (OSDI) score > 23 and a Non-Invasive Tear Break-Up Time (NIBUT) of less than 10 s. Participants attended 5 research visits. Participants underwent three sessions of Tixel® therapy on both eyes only at visits 1, 2, and 3. The initial 4 visits were spaced by a span of 2 weeks ± 5 days. The 5th appointment occurred 20 weeks after the 1st visit. During each visit, clinical measures including the OSDI score, the standard patient evaluation of ocular dryness questionnaire (SPEED) score, and NIBUT were documented. Tear samples, from the left eye only, were obtained during each visit and analysed using high-performance lipid chromatography to evaluate the lipid concentrations present. RESULTS: The study comprised 7 females and 3 males, with a mean age of 42 ± 9 years. No adverse occurrences were documented. A significant difference was noted in the mean OSDI score (45.11 ± 18.70 vs 21.72 ± 21.25, P < 0.001), the SPEED score (14.70 ± 1.70 vs 8.80 ± 6.12, P < 0.05), and the NIBUT (4.73 ± 2.37 vs 8.01 ± 2.32, P < 0.05) between visit 1 and visit 5. Despite individual variability in tear lipid content and the influence of sample volume, some participants showed an increase in total lipid levels following therapy. CONCLUSIONS: The study demonstrated a significant improvement in the signs and symptoms of dry eye disease following Tixel® treatment, with no adverse events observed during the investigation. The findings indicate that Tixel® treatment is a promising therapeutic option for evaporative dry eye disease, warranting further investigation into its effects on tear lipids.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Optometry and Vision Sciences Research Group, Aston University, Birmingham, United Kingdom. Electronic address: 210322284@aston.ac.uk.
- Biomaterials Research Unit, Engineering and Physical Sciences, Aston University, Birmingham, United Kingdom. Electronic address: franklvj@aston.ac.uk.
- Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid (UVa), Valladolid, Spain. Electronic address: marta.blanco.vazquez@uva.es.
- Optometry and Vision Sciences Research Group, Aston University, Birmingham, United Kingdom. Electronic address: s.a.naroo@aston.ac.uk.
- Optometry and Vision Sciences Research Group, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, Birmingham, United Kingdom. Electronic address: s.shah26@aston.ac.uk.
- Optometry and Vision Sciences Research Group, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, Birmingham, United Kingdom. Electronic address: r.gil-cazorla@aston.ac.uk.
Zitieren
APA
Rawal, B. R., Franklin, V. J., Blanco-Vázquez, M., Naroo, S. A., Shah, S., & Gil-Cazorla, R. (2026). Effect of a thermo-mechanical action device on symptoms, signs and tear lipid profile in patients with evaporative dry eye disease. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2026.102656
Vancouver
Rawal BR, Franklin VJ, Blanco-Vázquez M, Naroo SA, Shah S, Gil-Cazorla R. Effect of a thermo-mechanical action device on symptoms, signs and tear lipid profile in patients with evaporative dry eye disease. Contact Lens and Anterior Eye. 2026. doi:10.1016/j.clae.2026.102656
BibTeX
@article{Rawal2026,
author = {Rawal, Bhagyashree Rajesh and Franklin, Val J and Blanco-Vázquez, Marta and Naroo, Shehzad A and Shah, Sunil and Gil-Cazorla, Raquel},
title = {Effect of a thermo-mechanical action device on symptoms, signs and tear lipid profile in patients with evaporative dry eye disease},
journal = {Contact Lens and Anterior Eye},
year = {2026},
doi = {10.1016/j.clae.2026.102656}
}
EUVIMED