EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Fitting efficacy and ocular surface safety of digitally customized orthokeratology lenses in patients with moderate myopia and high curvature corneas

Jia Yu, Jinting Hu

Contact Lens and Anterior Eye · 2026

DOI: 10.1016/j.clae.2026.102649 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Contact Lens and Anterior Eye, 2026. Verfasst von Jia Yu und 1 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Huade Ophthalmology Hospital Co., Ltd., Beijing 100026, China. Electronic address: haidianyujia@126.com. Hauptthemen laut MEDLINE: Myopia, Orthokeratologic Procedures, Contact Lenses, Prosthesis Fitting. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Chengdu University of Traditional Chinese Medicine.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate fitting characteristics, ocular surface safety, and myopia control efficacy of digitally customized orthokeratology (OK) lenses in moderate myopia patients with high curvature corneas (flat K ≥ 44 D), with low-concentration atropine as an adjunct. METHODS: 126 patients were randomized into three groups: Group A (digitally customized OK lenses + 0.01% atropine, n = 42), Group B (conventional OK lenses + 0.01% atropine, n = 41), and Group C (single-vision spectacles, n = 43). Primary outcomes included fitting qualification rate, corneal epithelial integrity, and tear film stability; axial length change was a key secondary outcome. Multiple linear regression and sensitivity analysis were performed. RESULTS: Group A had a significantly higher fitting qualification rate than Group B (1 month: 95.2% vs 80.5%, P = 0.031; 12 months: 88.1% vs 73.2%, P = 0.068). It also showed better corneal epithelial integrity, tear film stability, and slower axial elongation than Groups B and C (all P < 0.05). Fitting qualification rate and intervention type were key predictors of axial length growth. CONCLUSION: Digitally customized orthokeratology lenses combined with 0.01% atropine can significantly improve the fitting accuracy for high curvature corneas. Corneal epithelial integrity is ensured by maintaining corneal epithelial thickness and reducing corneal fluorescein staining scores. Meanwhile, this combined intervention optimizes tear film stability, ensures ocular surface safety and achieves favorable myopia control efficacy. This combined regimen is recognized as an optimal contact lens correction option for myopia patients with high curvature corneas. The adjunctive effect of low-concentration atropine needs to be further verified in combination with lens fitting status.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyopiaOrthokeratologic ProceduresContact LensesProsthesis FittingCorneaHumansFemaleMaleAdultCorneal TopographyTreatment OutcomeYoung AdultRefraction, OcularAtropineAdolescent

Stichwörter der Autor:innen

Corneal epithelial integrityDigitally customized orthokeratology lensHigh curvature corneaLens fittingMyopia controlTear film stability

Substanzen

Atropine

Autor:innen und Institutionen

  • Beijing Huade Ophthalmology Hospital Co., Ltd., Beijing 100026, China. Electronic address: haidianyujia@126.com.
  • Beijing Huade Ophthalmology Hospital Co., Ltd., Beijing 100026, China.

Förderung

  • Chengdu University of Traditional Chinese Medicine

Zitieren

APA

Yu, J., & Hu, J. (2026). Fitting efficacy and ocular surface safety of digitally customized orthokeratology lenses in patients with moderate myopia and high curvature corneas. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2026.102649

Vancouver

Yu J, Hu J. Fitting efficacy and ocular surface safety of digitally customized orthokeratology lenses in patients with moderate myopia and high curvature corneas. Contact Lens and Anterior Eye. 2026. doi:10.1016/j.clae.2026.102649

BibTeX
@article{Yu2026,
  author = {Yu, Jia and Hu, Jinting},
  title = {Fitting efficacy and ocular surface safety of digitally customized orthokeratology lenses in patients with moderate myopia and high curvature corneas},
  journal = {Contact Lens and Anterior Eye},
  year = {2026},
  doi = {10.1016/j.clae.2026.102649}
}
Kostenlos starten →