EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator

Eduardo Esteban-Ibañez, Ainhoa Molina-Martín, Elena Martínez-Plaza, Carlos Dorronsoro, Enrique Gambra, David P Piñero

Contact Lens and Anterior Eye · 2025

DOI: 10.1016/j.clae.2025.102468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2025. Verfasst von Eduardo Esteban-Ibañez und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain; 2EyesVision SL, Madrid, Spain. Electronic address: e…. Hauptthemen laut MEDLINE: Presbyopia, Prosthesis Fitting, Visual Acuity, Contact Lenses. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación, Ministerio de Ciencia, Innovación y Universidades, Community of Madrid.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the feasibility of implementing fitting guides for multifocal contact lenses (MCLs) using the SimVis Gekko visual simulator and, through a preliminary assessment with a novel metric (3D-VA, which integrates visual acuity at multiple distances and patient visual needs), determine whether this combined approach can optimise initial MCL selection. METHODS: Twenty presbyopic subjects participated in this study using two methods to select on-eye MCLs from 4 manufacturers: (1) using the first step of the fitting guide, according to the patient's addition need, to provide the MCLs recommended by the manufacturer and, (2) using SimVis Gekko simulations to obtain MCLs providing better 3D-VA, between the first and the first-alternative step of the fitting guides. Clinical measurements and metric calculations (3D-VA, perceptual score module, and direct preference) were conducted to compare the visual performance of the on-eye MCLsselected by both methods when differences existed. RESULTS: SimVis Gekko selected the same combination of MCLs as the fitting guides in 59 % of the cases. In 28 %, SimVis Gekko chose the alternative step with differences greater than 0.05 in 3D-VA. In these latter cases, the 3D-VAsobtained with the on-eye MCLs indicated that SimVis Gekko selections were better in 62 % of cases, equal in 14 %, and worse in 24 %. The perceptual score module showed that SimVis Gekko selections were better in 62 % of cases, equal in 9 %, and worse in 29 %. The direct preference indicated that SimVis Gekko selections were better in 61 % of cases. Clinical measurements revealed that MCLsselected by SimVis Gekko had better Near Activity Visual Questionnaire scoresthan the fitting guide selection acrossall manufacturers (p = 0.02), indicating greater comfort and independence for near activities. CONCLUSIONS: SimVis Gekko can effectively replicate fitting guide steps and, in combinationwith the3D-VA metric, has the potential to become a tool that helps practitioners enhance MCL wearer satisfaction. This approach could improve the adoption and visual performance of MCLs among the presbyopic population,streamlining the fitting process.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PresbyopiaProsthesis FittingVisual AcuityContact LensesHumansMaleFemaleMiddle AgedComputer SimulationAdultAgedEquipment DesignFeasibility Studies

Stichwörter der Autor:innen

Fitting guidesMultifocal contact lensesPresbyopiaSimVis technology

Autor:innen und Institutionen

  • Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain; 2EyesVision SL, Madrid, Spain. Electronic address: eesteban@2eyesvision.com.
  • Group of Optics and Visual Perception (GOPV), Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
  • Group of Optics and Visual Perception (GOPV), Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain; University of Valladolid, Valladolid, Spain.
  • Institute of Optics 'Daza de Valdés', Spanish National Research Council, IO-CSIC, Madrid, Spain; 2EyesVision SL, Madrid, Spain.
  • 2EyesVision SL, Madrid, Spain.

Förderung

  • Ministerio de Ciencia e Innovación
  • Ministerio de Ciencia, Innovación y Universidades
  • Community of Madrid

Zitieren

APA

Esteban-Ibañez, E., Molina-Martín, A., Martínez-Plaza, E., Dorronsoro, C., Gambra, E., & Piñero, D. P. (2025). Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2025.102468

Vancouver

Esteban-Ibañez E, Molina-Martín A, Martínez-Plaza E, Dorronsoro C, Gambra E, Piñero DP. Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator. Contact Lens and Anterior Eye. 2025. doi:10.1016/j.clae.2025.102468

BibTeX
@article{EstebanIbaez2025,
  author = {Esteban-Ibañez, Eduardo and Molina-Martín, Ainhoa and Martínez-Plaza, Elena and Dorronsoro, Carlos and Gambra, Enrique and Piñero, David P},
  title = {Improving multifocal contact lens fitting by replicating their fitting guides using the SimVis Gekko visual simulator},
  journal = {Contact Lens and Anterior Eye},
  year = {2025},
  doi = {10.1016/j.clae.2025.102468}
}
Kostenlos starten →