EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudie

Effect of apical clearance rigid corneal contact lens fitting on keratoconus progression: a controlled longitudinal analysis

Tsung-Hsien Tsai, Jui-Hung Hsu, Chi-Chin Sun, Ching-Hsi Hsiao, Jiahn-Shing Lee, Ken-Kuo Lin

Contact Lens and Anterior Eye · 2025

DOI: 10.1016/j.clae.2025.102449 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Contact Lens and Anterior Eye, 2025. Verfasst von Tsung-Hsien Tsai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan; School of Medicine, College of Medicine, Chang Gung University, Taoyuan, …. Hauptthemen laut MEDLINE: Contact Lenses, Cornea, Keratoconus, Prosthesis Fitting. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Center for Big Data Analytics and Statistics, Chang Gung Memorial Hospital, Chang Gung Memorial Hospital, Linkou.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the impact of apical clearance rigid corneal contact lens (RCCL) fitting on keratoconus (KC) progression compared to untreated KC patients over a 12-month period. METHODS: This retrospective, controlled longitudinal study included 237 eyes with KC from two centers between 2018 and 2023. Following propensity score matching for baseline age and maximum keratometry (Kmax), 31 eyes each were assigned to untreated and RCCL groups. RCCLs were fitted using the apical clearance method. Assessments at baseline, 3, 6, and 12 months included best-corrected visual acuity (BCVA), Scheimpflug corneal tomography and higher-order aberrations (HOAs). KC progression was defined by any of the following: an increase in Kmax or anterior steep keratometry (K2) of >1.0 D, a decrease in thinnest corneal thickness (TCT) of > 10 μm, or a loss of >1 line of BCVA. Longitudinal changes were analyzed using generalized estimating equations (GEE). RESULTS: No significant differences in BCVA, tomographic indices, or HOAs were observed between the untreated and RCCL groups at baseline or during follow-up at 3 and 12 months (all p > 0.05). KC progression rates were comparable between the groups, occurring in 12.9 % of untreated eyes and 19.35 % of RCCL treated eyes by 12 months (p = 0.731). GEE analysis revealed a significant reduction in K2 at 3 months within the RCCL group (p = 0.003); however, no other significant longitudinal differences were detected within or between groups at any follow-up period. CONCLUSION: Apical clearance RCCL fitting did not significantly affect overall KC progression compared with no treatment over 12 months. However, the significant reduction in K2 at 3 months in the RCCL group suggests that one week of contact lens discontinuation may not be sufficient for the cornea to fully return to its natural state.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact LensesCorneaKeratoconusProsthesis FittingAdolescentAdultFemaleHumansMaleYoung AdultCorneal TopographyDisease ProgressionFollow-Up StudiesLongitudinal StudiesRetrospective StudiesVisual Acuity

Stichwörter der Autor:innen

Apical clearance fittingCorneal tomographyKeratoconusLongitudinal analysisRigid corneal contact lenses

Autor:innen und Institutionen

  • Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan; School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address: ophtsai@cgmh.org.tw.
  • Department of Medical Education, Chang Gung Memorial Hospital, Keelung, Taiwan.
  • Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Taiwan; School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
  • School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan.
  • School of Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taiwan. Electronic address: d12093@cgmh.org.tw.

Förderung

  • Center for Big Data Analytics and Statistics, Chang Gung Memorial Hospital
  • Chang Gung Memorial Hospital, Linkou

Zitieren

APA

Tsai, T. H., Hsu, J. H., Sun, C. C., Hsiao, C. H., Lee, J. S., & Lin, K. K. (2025). Effect of apical clearance rigid corneal contact lens fitting on keratoconus progression: a controlled longitudinal analysis. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2025.102449

Vancouver

Tsai TH, Hsu JH, Sun CC, Hsiao CH, Lee JS, Lin KK. Effect of apical clearance rigid corneal contact lens fitting on keratoconus progression: a controlled longitudinal analysis. Contact Lens and Anterior Eye. 2025. doi:10.1016/j.clae.2025.102449

BibTeX
@article{Tsai2025,
  author = {Tsai, Tsung-Hsien and Hsu, Jui-Hung and Sun, Chi-Chin and Hsiao, Ching-Hsi and Lee, Jiahn-Shing and Lin, Ken-Kuo},
  title = {Effect of apical clearance rigid corneal contact lens fitting on keratoconus progression: a controlled longitudinal analysis},
  journal = {Contact Lens and Anterior Eye},
  year = {2025},
  doi = {10.1016/j.clae.2025.102449}
}
Kostenlos starten →