EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of autologous serum and platelet-rich plasma in the treatment of severe dry eye and persistent epithelial defects

İbrahim Özlük, Bora Yüksel, Tuncay Küsbeci

Contact Lens and Anterior Eye · 2024

DOI: 10.1016/j.clae.2024.102247 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von İbrahim Özlük und 2 weiteren Autor:innen. Beteiligte Einrichtung: University of Health Sciences, Izmir Bozyaka Teaching Hospital, Department of Ophthalmology, Turkey. Hauptthemen laut MEDLINE: Platelet-Rich Plasma, Dry Eye Syndromes, Epithelium, Corneal, Serum. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the efficacy of topical autologous serum and platelet-rich plasma (PRP) in patients with severe dry eye and persistent epithelial defects. METHODS: Sixty-seven eyes of 42 patients including 12 Sjogren, 11 meibomian gland dysfunction, 8 post penetrating keratoplasty, 5 acne rosacea, 5 chemical burn and 3 neurotophic keratopathy were analyzed. Best corrected visual acuity, Schirmer, Ocular Surface Disease Index (OSDI), tear break-up time, Oxford staining scores were measured before the treatment and 1 month. One month scores of two groups were compared. RESULTS: Thirty three eyes received autologous serum and 34 received PRP. There was no statistically significant differences between two groups in ocular surface parameters at baseline. Statistically significant improvements were achieved in both groups in all parameters at 1 month (p < 0.05). Schirmer score improved from 7.9 ± 7.6 to 10.6 ± 8.4 mm in autologous serum (p < 0.001) and from 10.9 ± 9.5 to 13.3 ± 10.1 in PRP (p < 0.001); BUT from 4.3 ± 2.7 to 6.7 ± 3.4 s (p < 0.001) and 4.5 ± 3.0 to 6.0 ± 3.6 (p < 0.001); OSDI from 47.7 ± 14.7 to 25.7 ± 11.0 (p < 0.001) and from 54.1 ± 17.3 to 26.8 ± 11.0 (p < 0.001); Oxford score from 4.0 ± 1.0 to 1.3 ± 1.1 in (p < 0.001) and 3.9 ± 0.9 to 1.6 ± 1.3 (p < 0.001) respectively. Significant visual improvement was achieved with PRP from 0.81 ± 0.73 LogMAR to 0.72 ± 0.63 (p = 0.025), whereas insignificant with serum from 0.60 ± 0.65 to 0.57 ± 0.67 (p = 0.147). Mean epithelial healing time was 6.7 ± 4.7 (2-14) days in serum and 3.6 ± 1.9 (2-7) in PRP (p = 0.195). CONCLUSIONS: Both treatments are equally effective in severe dry eye and persistent epithelial defects. Although, visual gain is higher in PRP, autologous serum may be preferable due to low cost.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Platelet-Rich PlasmaDry Eye SyndromesEpithelium, CornealSerumVisual AcuityHumansFemaleMaleMiddle AgedAdultTreatment OutcomeOphthalmic SolutionsAgedTearsCorneal Diseases

Stichwörter der Autor:innen

Autologous PRPAutologous serumDry eyePersistent epithelial defect

Substanzen

Ophthalmic Solutions

Autor:innen und Institutionen

  • University of Health Sciences, Izmir Bozyaka Teaching Hospital, Department of Ophthalmology, Turkey.
  • University of Health Sciences, Izmir Bozyaka Teaching Hospital, Department of Ophthalmology, Turkey. Electronic address: drborayuksel@gmail.com.

Zitieren

APA

Özlük, İ., Yüksel, B., & Küsbeci, T. (2024). Comparison of autologous serum and platelet-rich plasma in the treatment of severe dry eye and persistent epithelial defects. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102247

Vancouver

Özlük İ, Yüksel B, Küsbeci T. Comparison of autologous serum and platelet-rich plasma in the treatment of severe dry eye and persistent epithelial defects. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2024.102247

BibTeX
@article{zlk2024,
  author = {Özlük, İbrahim and Yüksel, Bora and Küsbeci, Tuncay},
  title = {Comparison of autologous serum and platelet-rich plasma in the treatment of severe dry eye and persistent epithelial defects},
  journal = {Contact Lens and Anterior Eye},
  year = {2024},
  doi = {10.1016/j.clae.2024.102247}
}
Kostenlos starten →