The efficacy of a device-based approach to microorganism disinfection and protein removal for orthokeratology lenses in varied clinical circumstances

Yong-Li Zhou, Wan-Qing Jin, Ji-Wen Yang, Hong-Xin Song, Feng Chang, Fangfang Xia, Fen Zhang, Wei-Zhong Lan, Fan Lu

Contact Lens and Anterior Eye · 2024

DOI: 10.1016/j.clae.2023.102106 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Yong-Li Zhou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Aier School of Ophthalmology, Central South University, Changsha, Hunan, P.R. China. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Lens, Crystalline. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: RigidCare is an electrolysis-based device that recently obtained approval from the US's FDA to sterilise microorganisms and remove proteins for orthokeratology (O-K) lenses. The study was conducted to investigate the device's performance in varied clinical circumstances. METHODS: Trial lenses and private lenses were employed by O-K lens wearers from five hospitals for an evaluation of disinfection and sterilisation and an assessment of protein removal, respectively. Menicon multipurpose solution and protein remover were selected for use with the control group. Following the instructions, pre-cleaning lens samples, post-cleaning lens samples and residual solution samples of trial lenses of the experimental and control groups were collected for microorganism examinations by an experienced third-party testing organisation. The levels of protein deposition for these two approaches were rated by senior O-K experts. Categorical variables were analysed using statistical tests, such as the chi-squared test and Fisher's exact test. RESULTS: The microbial positive rate detected from the pre-cleaning and post-cleaning lens samples and the residual solution of the trial lenses for the experimental and control group was 4/76 vs 1/74 (P = 0.37), 1/76 vs 0/74 (P = 1.00) and 0/76 vs 8/74 (P = 0.006), respectively. Following protein removal, the experimental group exhibited a significantly higher overall proportion of lenses rated as 'clean' or with a 'mild deposit' (96.4 %, 79/82) compared to the control group (85.7 %, 66/77), with a significant difference (P < 0.05). CONCLUSION: This multi-center study demonstrated that RigidCare exhibited superior efficacy in disinfection, sterilisation and protein removal as compared to Menicon multipurpose solution and protein remover.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contact Lenses, HydrophilicLens, CrystallineHumansDisinfectionContact Lens Solutions

Stichwörter der Autor:innen

Care devicesElectrolysisO-K lensRGP lens disinfectionReal-world trial

Substanzen

Contact Lens Solutions

Autor:innen und Institutionen

  • Aier School of Ophthalmology, Central South University, Changsha, Hunan, P.R. China.
  • State Key Laboratory of Ophthalmology, Optometry and Visual Science, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medic…
  • Liaoning Aier Eye Hospital, Shenyang, Liaoning, China.
  • Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Department of Ophthalmology, General Hospital of the Central Theater Command of the People's Liberation Army of China, Wuhan, Hubei, China.
  • National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.

Zitieren

APA

Zhou, Y. L., Jin, W. Q., Yang, J. W., Song, H. X., Chang, F., Xia, F., Zhang, F., Lan, W. Z., & Lu, F. (2024). The efficacy of a device-based approach to microorganism disinfection and protein removal for orthokeratology lenses in varied clinical circumstances. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2023.102106

Vancouver

Zhou YL, Jin WQ, Yang JW, Song HX, Chang F, Xia F, et al. The efficacy of a device-based approach to microorganism disinfection and protein removal for orthokeratology lenses in varied clinical circumstances. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2023.102106

BibTeX
@article{Zhou2024,
  author = {Zhou, Yong-Li and Jin, Wan-Qing and Yang, Ji-Wen and Song, Hong-Xin and Chang, Feng and Xia, Fangfang and Zhang, Fen and Lan, Wei-Zhong and Lu, Fan},
  title = {The efficacy of a device-based approach to microorganism disinfection and protein removal for orthokeratology lenses in varied clinical circumstances},
  journal = {Contact Lens and Anterior Eye},
  year = {2024},
  doi = {10.1016/j.clae.2023.102106}
}
Kostenlos starten →