A first-in-human pilot study of a novel electrically-passive metamaterial-inspired resonator-based ocular sensor embedded contact lens monitoring intraocular pressure fluctuations
Contact Lens and Anterior Eye · 2024
DOI: 10.1016/j.clae.2023.102102 ↗Kurz gefasst
Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Ozgur Kaya und 11 weiteren Autor:innen. Beteiligte Einrichtung: Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye. Hauptthemen laut MEDLINE: Glaucoma, Contact Lenses. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Glaucoma is a leading cause of blindness with no cure, but early treatment and effective monitoring can often slow the progression of the disease. Monitoring of glaucoma is based on the measurement of intra-ocular pressure (IOP) that is a physiological parameter related to the mechanical state and parameters of the eye. Conventionally, diagnosing and assessing the progression of glaucoma is based on the method of measuring IOP discretely at clinics. Recent studies have demonstrated the importance of continuously monitoring IOP for 24 h to elucidate the effect of circadian rhythm. In this work, a metamaterial-inspired electrically-passive sensor-embedded contact lens is presented to monitor the IOP fluctuations based on a first-in-human pilot study. The sensor inside the contact lens is an electrically passive, metamaterial-based resonator that can be measured using a wearable antenna patch. The system has been tested with six healthy volunteers during an experiment to induce deliberate IOP changes via water-loading and placing the individuals in supine position using a recliner seat. The initial data compared with tonometer measurements suggest that the system can be used to assess the variation of IOP continuously.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye.
- Department of Ophthalmology, Koc University Medical School, Istanbul, Turkiye.
- Faculty of Engineering & Environment, University of Northumbria, Newcastle Upon Tyne, NE1 8ST, UK. Electronic address: hamdi.torun@northumbria.ac.uk.
- Department of Electrical and Electronics Engineering, Bogazici University, Bebek 34342 Istanbul, Turkiye.
Zitieren
APA
Kaya, O., Akif Aydin, M., Teymoori, M., Kaan Erden, O., Sadeghzadeh, S., Dedeoglu, U. O., Demir, S., Muhikanci, O., Sahin, A., Torun, H., Dundar, G., & Yalcinkaya, A. D. (2024). A first-in-human pilot study of a novel electrically-passive metamaterial-inspired resonator-based ocular sensor embedded contact lens monitoring intraocular pressure fluctuations. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2023.102102
Vancouver
Kaya O, Akif Aydin M, Teymoori M, Kaan Erden O, Sadeghzadeh S, Dedeoglu UO, et al. A first-in-human pilot study of a novel electrically-passive metamaterial-inspired resonator-based ocular sensor embedded contact lens monitoring intraocular pressure fluctuations. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2023.102102
BibTeX
@article{Kaya2024,
author = {Kaya, Ozgur and Akif Aydin, M and Teymoori, Morteza and Kaan Erden, Oguz and Sadeghzadeh, Seyedehayda and Dedeoglu, Ulas O and Demir, Saibe and Muhikanci, Omer and Sahin, Afsun and Torun, Hamdi and Dundar, Gunhan and Yalcinkaya, Arda D},
title = {A first-in-human pilot study of a novel electrically-passive metamaterial-inspired resonator-based ocular sensor embedded contact lens monitoring intraocular pressure fluctuations},
journal = {Contact Lens and Anterior Eye},
year = {2024},
doi = {10.1016/j.clae.2023.102102}
}
EUVIMED