Comparison of visual performance and image quality between a myopia-control contact lens and a single-vision contact lens
Contact Lens and Anterior Eye · 2023-10 · 46 (5) · 101891
DOI: 10.1016/j.clae.2023.101891 ↗Kurz gefasst
Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2023-10. Verfasst von Ding Han und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and S…. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Myopia. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
OBJECTIVE: This study aimed to evaluate the visual performance and image quality of concentric dual-focus-designed contact lenses (CLs) compared with single-vision CLs in myopic Chinese people. METHODS: Twenty myopic volunteers aged between 18 and 26 years were recruited at a university eye hospital to wear both defocus-incorporated soft contact (DISC) lenses and single-vision CLs for 1 week in random order. High- and low-contrast visual acuity (VA), contrast sensitivity (CS), ocular higher-order aberrations (HOA), Strehl ratio and the Quality of Vision (QoV) questionnaire were assessed with each type of CL at weekly follow-up. RESULTS: Distance VA was not affected by DISC lenses compared to single-vision CLs in either high (p = 0.414) or low contrast (p = 0.431). However, there was a significant reduction in low-contrast near VA with DISC lenses compared with single-vision CLs (p = 0.011). The differences of CS between DISC lenses and single-vision CLs were significantly associated with lighting conditions and spatial frequencies (F = 128.81, P < 0.001). Compared with single-vision CLs, wavefront aberrations of DISC lenses were significantly increased in total HOA, trefoil, and spherical aberrations for either 3.0 mm or 6.0 mm pupil size. The Strehl ratio wearing DISC lenses reduced significantly compared to the single-vision CLs (p < 0.001) at a pupil diameter of 6.0 mm. QoV scores were higher overall (p = 0.026) and frequency (p = 0.019) with DISC lenses than with single-vision CLs, indicating poorer visual performance. CONCLUSION: DISC lenses provide satisfactory distance VA. However, the higher scores of the QoV questionnaire with DISC lenses may be related to decreased CS at medium or high spatial frequencies and increased higher-order aberrations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin 3…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Han, D., Zhang, Z., Li, B., Rong, H., Song, D., Du, B., & Wei, R. (2023). Comparison of visual performance and image quality between a myopia-control contact lens and a single-vision contact lens. Contact Lens and Anterior Eye, 46(5), 101891. https://doi.org/10.1016/j.clae.2023.101891
Vancouver
Han D, Zhang Z, Li B, Rong H, Song D, Du B, et al. Comparison of visual performance and image quality between a myopia-control contact lens and a single-vision contact lens. Contact Lens and Anterior Eye. 2023;46(5):101891. doi:10.1016/j.clae.2023.101891
BibTeX
@article{Han2023,
author = {Han, Ding and Zhang, Ziyu and Li, Bingqin and Rong, Hua and Song, Desheng and Du, Bei and Wei, Ruihua},
title = {Comparison of visual performance and image quality between a myopia-control contact lens and a single-vision contact lens},
journal = {Contact Lens and Anterior Eye},
year = {2023},
volume = {46},
number = {5},
pages = {101891},
doi = {10.1016/j.clae.2023.101891}
}
EUVIMED