Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2023. Verfasst von Jing Zhai und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Hauptthemen laut MEDLINE: Contact Lenses, Hydrophilic, Eyelid Diseases. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To test the changes of meibomian gland (MG) morphology using an artificial intelligence (AI) analytic system in asymptomatic children wearing overnight orthokeratology (OOK) and soft contact lens (SCL). METHODS: A retrospective study was conducted including 89 participants treated with OOK and 70 participants with SCL. Tear meniscus height (TMH), noninvasive tear breakup time (NIBUT), and meibography were obtained using Keratograph 5 M. MG tortuosity, height, width, density, and vagueness value were measured using an artificial intelligence (AI) analytic system. RESULTS: In an average of 20.80 ± 10.83 months follow-up, MG width of the upper eyelid significantly increased and MG vagueness value significantly decreased after OOK and SCL treatment (all P 0.05). The results from the GEE model demonstrated that OOK treatment positively affected MG tortuosity of both upper and lower eyelids (P < 0.001; P = 0.041, respectively) and MG width of the upper eyelid (P = 0.038), while it negatively affected MG density of the upper eyelid (P = 0.036) and MG vagueness value of both upper and lower eyelids (P < 0.001; P < 0.001, respectively). SCL treatment positively affected MG width of both upper and lower eyelids (P < 0.001; P = 0.049, respectively) as well as MG height of the lower eyelid (P = 0.009) and tortuosity of the upper eyelid, (P = 0.034) while it negatively affected MG vagueness value of both upper and lower eyelids (P < 0.001; P < 0.001, respectively). However, no significant relationship was found between the treatment duration and TMH, NIBUT, MG morphological parameters in OOK group. SCL treatment duration negatively affected MG height of the lower eyelid (P = 0.002). CONCLUSIONS: OOK and SCL treatment in asymptomatic children can influence MG morphology. The AI analytic system may be an effective method to facilitate the quantitative detection of MG morphological changes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
- Zhejiang Provincial Center for Medical Science Technology and Education Development, Hangzhou 310009, China.
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Electronic address: dq@mail.eye.ac.cn.
Zitieren
APA
Zhai, J., Hou, L., Yao, Y., Lian, H., Chen, S., Xu, Y., & Dai, Q. (2023). The influence of overnight orthokeratology and soft contact lens on the meibomian gland evaluated using an artificial intelligence analytic system. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2023.101841
Vancouver
Zhai J, Hou L, Yao Y, Lian H, Chen S, Xu Y, et al. The influence of overnight orthokeratology and soft contact lens on the meibomian gland evaluated using an artificial intelligence analytic system. Contact Lens and Anterior Eye. 2023. doi:10.1016/j.clae.2023.101841
BibTeX
@article{Zhai2023,
author = {Zhai, Jing and Hou, Lijie and Yao, Yixuan and Lian, Hengli and Chen, Siping and Xu, Yeqing and Dai, Qi},
title = {The influence of overnight orthokeratology and soft contact lens on the meibomian gland evaluated using an artificial intelligence analytic system},
journal = {Contact Lens and Anterior Eye},
year = {2023},
doi = {10.1016/j.clae.2023.101841}
}
EUVIMED