Clinical outcomes and complications of fluid-filled scleral lens devices for the management of limbal stem cell deficiency
Contact Lens and Anterior Eye · 2023-02 · 46 (1) · 101528
DOI: 10.1016/j.clae.2021.101528 ↗Kurz gefasst
Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2023-02. Verfasst von Clémence Bonnet und 4 weiteren Autor:innen. Beteiligte Einrichtung: Stein Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, USA; Ophthalmology Department, Cochin Hospital, AP-HP, F…. Hauptthemen laut MEDLINE: Corneal Diseases, Limbus Corneae, Limbal Stem Cell Deficiency. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, University of Southern California.
Abstract (Originalsprache)
AIMS: To evaluate the clinical and visual outcomes of fluid-filled scleral lens devices (SL) wear in patients with limbal stem cell deficiency (LSCD). DESIGN: Retrospective consecutive case series. METHODS: 27 eyes with LSCD confirmed by in vivo confocal microscopy at the Stein Eye Institute and fitted with SL were included. Correlations between corrected distance visual acuity (CDVA) and LSCD stage determined by clinical grading were performed between baseline (after the SL fit) and the last follow-up (the time of discontinuation of SL wear or the last visit in eyes in which SL were continued). In a subset of patients that had worsened LSCD while using SL, anterior segment optical coherence tomography (AS-OCT) and anterior segment fluorescein angiogram (AS-FA) were performed. RESULTS: Baseline LSCD grading was stage I in 12 eyes (44.4%), stage 2 in 12 eyes (44.4%), and stage III in 3 eyes (11.1%). At the last follow-up, CDVA was improved in 7 eyes (25.9%), remained stable in 13 eyes (48.1%) and decreased in 7 eyes (25.9%, P = 0.16). The LSCD stage was improved in 7 eyes (25.9%), remained stable in 8 eyes (29.6%) and worsened in 12 eyes (44.4%, P = 0.10). AS-OCT and AS-FA, performed in 5 eyes, showed limbal compression and delayed fluorescein filling. CONCLUSION: SL can improve visual acuity and maintain the ocular surface in the majority of eyes. Worsening of the ocular surface might be a result of limbal hypoxia. Close monitoring of SL fit is necessary in these compromised eyes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Stein Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, USA; Ophthalmology Department, Cochin Hospital, AP-HP, F-75014, Paris University, Paris, France.
- Stein Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, USA.
- David Geffen School of Medicine, Division of General Internal Medicine and Health Services Research, University of California, Los Angeles, USA.
- Stein Eye Institute, David Geffen School of Medicine, University of California, Los Angeles, USA; Molecular Biology Institute, University of California, Los Angeles, USA. Electronic address: deng@jsei.ucla.edu.
Förderung
- NEI NIH HHS
- University of Southern California
Zitieren
APA
Bonnet, C., Lee, A., Shibayama, V. P., Tseng, C. H., & Deng, S. X. (2023). Clinical outcomes and complications of fluid-filled scleral lens devices for the management of limbal stem cell deficiency. Contact Lens and Anterior Eye, 46(1), 101528. https://doi.org/10.1016/j.clae.2021.101528
Vancouver
Bonnet C, Lee A, Shibayama VP, Tseng CH, Deng SX. Clinical outcomes and complications of fluid-filled scleral lens devices for the management of limbal stem cell deficiency. Contact Lens and Anterior Eye. 2023;46(1):101528. doi:10.1016/j.clae.2021.101528
BibTeX
@article{Bonnet2023,
author = {Bonnet, Clémence and Lee, Andrew and Shibayama, Vivian P and Tseng, Chi-Hong and Deng, Sophie X},
title = {Clinical outcomes and complications of fluid-filled scleral lens devices for the management of limbal stem cell deficiency},
journal = {Contact Lens and Anterior Eye},
year = {2023},
volume = {46},
number = {1},
pages = {101528},
doi = {10.1016/j.clae.2021.101528}
}
EUVIMED