EUVIMEDEUVIMED entdecken
Kommentar

Deep Learning-based 12-Lead Electrocardiogram for Low Left Ventricular Ejection Fraction Detection in Patients

Yuxin Hou, Zhiping Fan, Jiaqi Li, Zi Zeng, Gang Lv, Jingsheng Lin, Liang Zhou, Tao Wu, Qing Cao

Canadian Journal of Cardiology · 2025

DOI: 10.1016/j.cjca.2024.09.018 ↗

Kurz gefasst

Kommentar in der Zeitschrift Canadian Journal of Cardiology, 2025. Verfasst von Yuxin Hou und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; Centre for Collaborative Research, Shan…. Hauptthemen laut MEDLINE: Deep Learning, Stroke Volume, Electrocardiography, Ventricular Dysfunction, Left. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Reduced left ventricular ejection fraction (LVEF) initiates heart failure, and promptly identifying low ejection fraction is crucial for managing progression and averting mortality. In this study we developed an artificial intelligence-enabled electrocardiogram (AI-ECG) algorithm to identify patients with low ejection fraction and predict LVEF values. METHODS: The electrocardiogram data were used as input, and the algorithm generated the probability of the patient suffering a low ejection fraction and estimated the LVEF value. A 5-year follow-up study on a group of individuals who initially had normal LVEF values was also performed. Furthermore, external validation of the algorithm performance was conducted using the Medical Information Mart for Intensive Care-IV database. RESULTS: The algorithm's performance on the test set yielded an area under the curve value of 0.965 for detecting LVEF ≤ 50%. The algorithm had an accuracy of 92.8%, sensitivity of 88.8%, and specificity of 92.9%. For LVEF regression, the method showed a mean absolute error of 5.28 (95% confidence interval, 5.23-5.33) for the testing set. Additionally, the algorithm obtained an area under the curve value of 0.848 and a mean absolute error value of 9.56 during external validation. Patients with false positive results had a significantly greater likelihood of developing a low ejection fraction compared with patients who received true negative results (26.2% vs 2.0%; P < 0.0001). CONCLUSIONS: The AI-ECG algorithm is capable of identifying low ejection fraction in patients with high accuracy. The AI-ECG algorithm is an efficient, prompt, and cost-effective screening tool for early heart failure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningStroke VolumeElectrocardiographyVentricular Dysfunction, LeftHeart FailureVentricular Function, LeftHumansFemaleMaleAgedMiddle AgedAlgorithmsFollow-Up Studies

Autor:innen und Institutionen

  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; Centre for Collaborative Research, Shanghai University of Medicine and Health Sciences, Shanghai, China.
  • College of Medical Imaging, Shanghai University of Medicine and Health Sciences, Shanghai, China.
  • Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Centre for Collaborative Research, Shanghai University of Medicine and Health Sciences, Shanghai, China.
  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China; Centre for Collaborative Research, Shanghai University of Medicine and Health Sciences, Shanghai, China; Chin…
  • Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address: cq30553@rjh.com.cn.

Zitieren

APA

Hou, Y., Fan, Z., Li, J., Zeng, Z., Lv, G., Lin, J., Zhou, L., Wu, T., & Cao, Q. (2025). Deep Learning-based 12-Lead Electrocardiogram for Low Left Ventricular Ejection Fraction Detection in Patients. Canadian Journal of Cardiology. https://doi.org/10.1016/j.cjca.2024.09.018

Vancouver

Hou Y, Fan Z, Li J, Zeng Z, Lv G, Lin J, et al. Deep Learning-based 12-Lead Electrocardiogram for Low Left Ventricular Ejection Fraction Detection in Patients. Canadian Journal of Cardiology. 2025. doi:10.1016/j.cjca.2024.09.018

BibTeX
@article{Hou2025,
  author = {Hou, Yuxin and Fan, Zhiping and Li, Jiaqi and Zeng, Zi and Lv, Gang and Lin, Jingsheng and Zhou, Liang and Wu, Tao and Cao, Qing},
  title = {Deep Learning-based 12-Lead Electrocardiogram for Low Left Ventricular Ejection Fraction Detection in Patients},
  journal = {Canadian Journal of Cardiology},
  year = {2025},
  doi = {10.1016/j.cjca.2024.09.018}
}
Kostenlos starten →