Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention
Canadian Journal of Cardiology · 2025
DOI: 10.1016/j.cjca.2024.09.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Cardiology, 2025. Verfasst von Ming Zeng und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Second Affiliated Hospital of Harbin Medical University, National Key Laboratory of Frigid Zone Cardiovascular Diseases, an…. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Percutaneous Coronary Intervention, Fractional Flow Reserve, Myocardial, Acute Coronary Syndrome. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Optical flow ratio (OFR) is a novel computational fractional flow reserve derived from optical coherence tomography (OCT). However, the impact of combining post-stenting morphology (OCT) and physiology (OFR) remains largely unknown. METHODS: OCT and OFR were analysed at an independent core laboratory. Target lesion failure (TLF) was defined as the composite of cardiac death, target lesion myocardial infarction, and target lesion revascularisation. Suboptimal stent deployment was identified with at least 1 TLF-related OCT or OFR characteristic. RESULTS: A total of 448 patients with acute coronary syndrome (459 vessels) were assessed. Stent expansion < 80%, minimal stent area < 4.5 mm2, stent edge lipid-rich plaque and OFR < 0.90 were independent predictors of TLF (all P < 0.001). Patients with OCT-suboptimal (adjusted hazard ratio [aHR] 7.88, 95% CI 2.73-22.72,-P < 0.001) or OFR-suboptimal (aHR 5.78, 95% CI 2.54-13.14; P < 0.001) stent deployment showed significantly higher risk of TLF compared with those with optimal stent deployment, with a significant interaction (Pinteraction < 0.001). OCT and OFR both-suboptimal stent deployment was confirmed as an independent predictor of TLF (aHR 9.39, 95% CI 4.25-20.76; P < 0.001). CONCLUSIONS: Combined OCT and OFR conferred an optimal reclassification of stent deployment, which may aid in decision making regarding a tailored PCI strategy for optimal stent deployment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cardiology, Second Affiliated Hospital of Harbin Medical University, National Key Laboratory of Frigid Zone Cardiovascular Diseases, and Key Laboratory of Medical Ischemia, Chinese Ministry of Education, H…
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Electronic address: sxtu@sjtu.edu.cn.
Zitieren
APA
Zeng, M., Chu, M., Xu, L., Yi, B., Yu, W., Sun, Q., Zhang, Y., Liu, Y., Zhao, C., Weng, Z., He, L., Qin, Y., Xu, Y., Liu, H., Wang, N., Feng, X., Koniaeva, E., Mohammad, D., Hu, S., …, & Jia, H. (2025). Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention. Canadian Journal of Cardiology. https://doi.org/10.1016/j.cjca.2024.09.002
Vancouver
Zeng M, Chu M, Xu L, Yi B, Yu W, Sun Q, et al. Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention. Canadian Journal of Cardiology. 2025. doi:10.1016/j.cjca.2024.09.002
BibTeX
@article{Zeng2025,
author = {Zeng, Ming and Chu, Miao and Xu, Liangxiao and Yi, Boling and Yu, Wei and Sun, Qianhui and Zhang, Yixuan and Liu, Yue and Zhao, Chen and Weng, Ziqian and He, Luping and Qin, Yuhan and Xu, Yishuo and Liu, Huimin and Wang, Ning and Feng, Xue and Koniaeva, Ekaterina and Mohammad, Diler and Hu, Sining and Tu, Shengxian and Yu, Bo and Jia, Haibo},
title = {Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention},
journal = {Canadian Journal of Cardiology},
year = {2025},
doi = {10.1016/j.cjca.2024.09.002}
}
EUVIMED