EUVIMEDEUVIMED entdecken
Crossref

Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention

Ming Zeng, Miao Chu, Liangxiao Xu, Boling Yi, Wei Yu, Qianhui Sun, Yixuan Zhang, Yue Liu, Chen Zhao, Ziqian Weng, Luping He, Yuhan Qin und 10 weitere

Canadian Journal of Cardiology · 2025

DOI: 10.1016/j.cjca.2024.09.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Canadian Journal of Cardiology, 2025. Verfasst von Ming Zeng und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Second Affiliated Hospital of Harbin Medical University, National Key Laboratory of Frigid Zone Cardiovascular Diseases, an…. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Percutaneous Coronary Intervention, Fractional Flow Reserve, Myocardial, Acute Coronary Syndrome. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Optical flow ratio (OFR) is a novel computational fractional flow reserve derived from optical coherence tomography (OCT). However, the impact of combining post-stenting morphology (OCT) and physiology (OFR) remains largely unknown. METHODS: OCT and OFR were analysed at an independent core laboratory. Target lesion failure (TLF) was defined as the composite of cardiac death, target lesion myocardial infarction, and target lesion revascularisation. Suboptimal stent deployment was identified with at least 1 TLF-related OCT or OFR characteristic. RESULTS: A total of 448 patients with acute coronary syndrome (459 vessels) were assessed. Stent expansion < 80%, minimal stent area < 4.5 mm2, stent edge lipid-rich plaque and OFR < 0.90 were independent predictors of TLF (all P < 0.001). Patients with OCT-suboptimal (adjusted hazard ratio [aHR] 7.88, 95% CI 2.73-22.72,-P < 0.001) or OFR-suboptimal (aHR 5.78, 95% CI 2.54-13.14; P < 0.001) stent deployment showed significantly higher risk of TLF compared with those with optimal stent deployment, with a significant interaction (Pinteraction < 0.001). OCT and OFR both-suboptimal stent deployment was confirmed as an independent predictor of TLF (aHR 9.39, 95% CI 4.25-20.76; P < 0.001). CONCLUSIONS: Combined OCT and OFR conferred an optimal reclassification of stent deployment, which may aid in decision making regarding a tailored PCI strategy for optimal stent deployment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherencePercutaneous Coronary InterventionFractional Flow Reserve, MyocardialAcute Coronary SyndromeHumansMaleFemaleMiddle AgedAgedStentsCoronary VesselsCoronary Angiography

Autor:innen und Institutionen

  • Department of Cardiology, Second Affiliated Hospital of Harbin Medical University, National Key Laboratory of Frigid Zone Cardiovascular Diseases, and Key Laboratory of Medical Ischemia, Chinese Ministry of Education, H…
  • Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Electronic address: sxtu@sjtu.edu.cn.

Zitieren

APA

Zeng, M., Chu, M., Xu, L., Yi, B., Yu, W., Sun, Q., Zhang, Y., Liu, Y., Zhao, C., Weng, Z., He, L., Qin, Y., Xu, Y., Liu, H., Wang, N., Feng, X., Koniaeva, E., Mohammad, D., Hu, S., …, & Jia, H. (2025). Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention. Canadian Journal of Cardiology. https://doi.org/10.1016/j.cjca.2024.09.002

Vancouver

Zeng M, Chu M, Xu L, Yi B, Yu W, Sun Q, et al. Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention. Canadian Journal of Cardiology. 2025. doi:10.1016/j.cjca.2024.09.002

BibTeX
@article{Zeng2025,
  author = {Zeng, Ming and Chu, Miao and Xu, Liangxiao and Yi, Boling and Yu, Wei and Sun, Qianhui and Zhang, Yixuan and Liu, Yue and Zhao, Chen and Weng, Ziqian and He, Luping and Qin, Yuhan and Xu, Yishuo and Liu, Huimin and Wang, Ning and Feng, Xue and Koniaeva, Ekaterina and Mohammad, Diler and Hu, Sining and Tu, Shengxian and Yu, Bo and Jia, Haibo},
  title = {Value of Combined Optical Coherence Tomography and Optical Flow Ratio Measurements After Percutaneous Coronary Intervention},
  journal = {Canadian Journal of Cardiology},
  year = {2025},
  doi = {10.1016/j.cjca.2024.09.002}
}
Kostenlos starten →