EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Cuerdas artificiales de ePTFE: ¿imprescindibles en las técnicas de preservación mitral actuales?

José L. Pomar, José M. Revuelta, Robert Frater

Cirugía Cardiovascular · 2013

DOI: 10.1016/j.circv.2013.09.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cirugía Cardiovascular, 2013. Verfasst von José L. Pomar und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recibido el 4 de septiembre de 2013 Aceptado el 5 de septiembre de 2013 Hace casi cincuenta, si, cincuenta a ños, se empezó a hablar de la posibilidad de sustituir las cuerdas tendinosas de la mitral rotas o distorsionadas por diferentes procesos inflamatorios o degenerativos.Robert Frater, 1 fue uno de quienes empezó estudiando la utilización de pericardio autólogo para ello, con resultados iniciales buenos pero a medio plazo poco esperanzadores por un exacerbado proceso de cicatrización.Tras diversos estudios en la oveja con diversos materiales (hominjertos, autoinjertos, xenoinjertos e incluso polímeros) fue de manera casual cuando empezó a probar otros materiales como los conductos vasculares de GoreTex observando un excelente comportamiento e incorporación tisular.Pero dejemos a Bob Frater que sea él mismo quien relate como fue la historia. . . «I saw my first open heart operation on SaturdayOct 15 1955 as a Mayo Clinic surgical fellow in training.My thesis for a Master's degree was "Develop a Mitral Valve Prosthesis.»The first step was to understand how the finger print irregularity of normal anatomy worked to allow free flow in diastole and tight competence in diastole.The answer was that 1) wherever leaflets met in closure the lengths of the cords controlling the free edges whether they were long or short, arising directly from the papillary muscle or as a branch of another cord, were exactly right to keep the edges parallel and 2) that the systolic annular area was invariably less than the sum of the leaflet area by between a quarter and a third.I started repairing insufficient mitral valves myself in South Africa in 1962.Rheumatics with insufficiency produced by diseased elongated anterior leaflet cords were commonly seen.I used autogenous pericardium to replace these cords with excellent initial success.These new cords eventually failed because of excessive host healing.We continued the search for the right material for cordal replacement using autograft, homograft, xenograft and polymer material with various treatments.Our goal was that the neocord would be covered by a thin layer of natural tissue and would retain indefinitely flexibility and the dimensions chosen by the surgeon.

Zitieren

APA

Pomar, J. L., Revuelta, J. M., & Frater, R. (2013). Cuerdas artificiales de ePTFE: ¿imprescindibles en las técnicas de preservación mitral actuales?. Cirugía Cardiovascular. https://doi.org/10.1016/j.circv.2013.09.001

Vancouver

Pomar JL, Revuelta JM, Frater R. Cuerdas artificiales de ePTFE: ¿imprescindibles en las técnicas de preservación mitral actuales?. Cirugía Cardiovascular. 2013. doi:10.1016/j.circv.2013.09.001

BibTeX
@article{Pomar2013,
  author = {Pomar, José L. and Revuelta, José M. and Frater, Robert},
  title = {Cuerdas artificiales de ePTFE: ¿imprescindibles en las técnicas de preservación mitral actuales?},
  journal = {Cirugía Cardiovascular},
  year = {2013},
  doi = {10.1016/j.circv.2013.09.001}
}
Kostenlos starten →