EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

End-Expiratory Transpulmonary Pressure Close to 0 and Clinical Outcomes in Pediatric ARDS

Yukie Ito, Daniel Chang, Justin C. Hotz, Meryl Vedrenne-Cloquet, Muneyuki Takeuchi, Bhushan H. Katira, Anoopindar K. Bhalla, Christopher J.L. Newth, Robinder G. Khemani

CHEST Critical Care · 2026-12 · 4 (4) · 100308

DOI: 10.1016/j.chstcc.2026.100308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CHEST Critical Care, 2026-12. Verfasst von Yukie Ito und 8 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Heart Lung and Blood Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Positive end-expiratory pressure (PEEP) titration targeting end-expiratory transpulmonary pressure (EEPL) close to 0 was associated with favorable clinical outcomes in a secondary analysis of the EPVent-2 trial in adults with ARDS. However, its relevance in children remains unknown. Research Question Is EEPL close to 0 associated with 28-day ventilator-free days (VFDs) in pediatric ARDS (PARDS)? Study Design and Methods We conducted a post hoc secondary analysis of a randomized controlled trial enrolling children with PARDS at a single center. EELP close to 0 was defined as –2 to +2 cm H 2 O. The primary outcome was 28-day VFDs, with ICU mortality and length of mechanical ventilation in survivors evaluated as its components. Secondary outcomes were respiratory system compliance and Pao 2 to Fio 2 ratio.

Results

One hundred ninety-eight patients were included. Median EEPL was –0.1 cm H 2 O (interquartile range [IQR], –2.5 to 1.9 cm H 2 O), median PEEP was 10.3 cm H 2 O (IQR, 8.3-12.3 cm H 2 O), and median end-expiratory esophageal pressure was 10.9 cm H 2 O (IQR, 8.6-13.3 cm H 2 O). In primary analyses, EEPL close to 0 was not associated with more 28-day VFDs, lower ICU mortality, or shorter length of mechanical ventilation in survivors. In secondary analyses, it was not associated with respiratory system compliance or Pao 2 to Fio 2 ratio.

Interpretation

In this cohort, EEPL close to 0 was not associated with favorable clinical outcomes in PARDS, nor with respiratory mechanics or oxygenation. Prospective titration studies are needed to clarify the physiologic relevance of EEPL in PARDS.

Förderung

  • National Heart Lung and Blood Institute

Zitieren

APA

Ito, Y., Chang, D., Hotz, J. C., Vedrenne-Cloquet, M., Takeuchi, M., Katira, B. H., Bhalla, A. K., Newth, C. J., & Khemani, R. G. (2026). End-Expiratory Transpulmonary Pressure Close to 0 and Clinical Outcomes in Pediatric ARDS. CHEST Critical Care, 4(4), 100308. https://doi.org/10.1016/j.chstcc.2026.100308

Vancouver

Ito Y, Chang D, Hotz JC, Vedrenne-Cloquet M, Takeuchi M, Katira BH, et al. End-Expiratory Transpulmonary Pressure Close to 0 and Clinical Outcomes in Pediatric ARDS. CHEST Critical Care. 2026;4(4):100308. doi:10.1016/j.chstcc.2026.100308

BibTeX
@article{Ito2026,
  author = {Ito, Yukie and Chang, Daniel and Hotz, Justin C. and Vedrenne-Cloquet, Meryl and Takeuchi, Muneyuki and Katira, Bhushan H. and Bhalla, Anoopindar K. and Newth, Christopher J.L. and Khemani, Robinder G.},
  title = {End-Expiratory Transpulmonary Pressure Close to 0 and Clinical Outcomes in Pediatric ARDS},
  journal = {CHEST Critical Care},
  year = {2026},
  volume = {4},
  number = {4},
  pages = {100308},
  doi = {10.1016/j.chstcc.2026.100308}
}
Kostenlos starten →