ICU Implementation Determinants and Delivery of Lung Protective Ventilation
CHEST Critical Care · 2026-03 · 4 (1) · 100240
DOI: 10.1016/j.chstcc.2026.100240 ↗Kurz gefasst
Fachartikel in der Zeitschrift CHEST Critical Care, 2026-03. Verfasst von Chad H Hochberg und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care Medicine (C. H. H., S. K. S., T. J. I., D. N. H., and M. N. E.), Department of Medicine (S. A. E.), Departmen…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, National Heart Lung and Blood Institute.
Abstract (Originalsprache)
BACKGROUND: Lung protective ventilation (LPV) improves mortality in patients with ARDS and is applied widely in other patients receiving mechanical ventilation. Despite strong evidence, LPV is implemented inconsistently. RESEARCH QUESTION: Are staff-rated ICU implementation determinants associated with delivery of patient-level LPV delivery. STUDY DESIGN AND METHODS: We conducted a cross-sectional survey of ICU clinical staff (January-June 2024) and a retrospective study of patients with hypoxemic respiratory failure receiving mechanical ventilation (January 2023-December 2024). We assessed staff-rated implementation determinants using validated surveys including domains for implementation culture (eg, team cooperation), staff stress, and available resources. We assessed the association of ICU-level survey scores with patient-level LPV (defined as tidal volume [VT] ≤ 6.5 mL/kg of perdicted body weight (PBW) and plateau pressure ≤ 30 cm H2O), and, as a complementary secondary outcome, hours spent at VT > 8 mL/kg PBW on day 1 of mechanical ventilation. We used mixed-effects negative binomial models including LPV hours as the outcome, eligible time as an offset, patient and ICU covariates, and a random effect for ICU. RESULTS: Survey measures from 469 ICU staff (50% response rate) were incorporated into the cohort of 2,120 patients across 5 hospitals and 14 ICUs. Median percentage compliance with LPV on day 1 was 68% (interquartile range, 0%-100%). A 1-SD increase in ICU implementation culture score was not associated with LPV (adjusted rate ratio [aRR], 1.04 [95% CI, 0.95-1.14]; P = .37), but was associated with less time at VT > 8 mL/kg PBW (aRR, 0.48 [95% CI, 0.32-0.71]; P 8 mL/kg (aRR, 1.71 [95% CI, 1.19-2.45]; P 8 mL/kg PBW. INTERPRETATION: In this multihospital study, ICU implementation determinants were associated with receiving VT >8 mL/kg PBW, but not with a stricter LPV definition. These findings may inform development of interventions to enhance ICU implementation determinants and improve LPV delivery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary and Critical Care Medicine (C. H. H., S. K. S., T. J. I., D. N. H., and M. N. E.), Department of Medicine (S. A. E.), Department of Pediatrics (K. J. P.), the Bloomberg School of Public Health (T.…
Förderung
- NHLBI NIH HHS
- National Heart Lung and Blood Institute
Zitieren
APA
Hochberg, C. H., Emetu, S. A., Psoter, K. J., Sahetya, S. K., Kerlin, M. P., Iwashyna, T. J., Hager, D. N., & Eakin, M. N. (2026). ICU Implementation Determinants and Delivery of Lung Protective Ventilation. CHEST Critical Care, 4(1), 100240. https://doi.org/10.1016/j.chstcc.2026.100240
Vancouver
Hochberg CH, Emetu SA, Psoter KJ, Sahetya SK, Kerlin MP, Iwashyna TJ, et al. ICU Implementation Determinants and Delivery of Lung Protective Ventilation. CHEST Critical Care. 2026;4(1):100240. doi:10.1016/j.chstcc.2026.100240
BibTeX
@article{Hochberg2026,
author = {Hochberg, Chad H and Emetu, Sophia A and Psoter, Kevin J and Sahetya, Sarina K and Kerlin, Meeta P and Iwashyna, Theodore J and Hager, David N and Eakin, Michelle N},
title = {ICU Implementation Determinants and Delivery of Lung Protective Ventilation},
journal = {CHEST Critical Care},
year = {2026},
volume = {4},
number = {1},
pages = {100240},
doi = {10.1016/j.chstcc.2026.100240}
}
EUVIMED