EUVIMEDEUVIMED entdecken
Crossref

Detection of estrogens using 2-furoyl chloride derivatization coupled with ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry

Qingyu Ding, Tianyou Zhang, Peng Zhang, Weiye Chen, Jiayi Li, Guixin Dong, Guanhua Wang

Journal of Chromatography A · 2026-11 · 467604

DOI: 10.1016/j.chroma.2026.467604 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026-11. Verfasst von Qingyu Ding und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, South China Agricultural University, Guangzhou, 510642, Guangdong, PR China. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Estrone (E1) and estradiol (E2) are important steroid hormones that require reliable analytical methods for their determination in biological samples. In this study, a method combining 2-furoyl chloride derivatization with ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed for the determination of E1 and E2 in serum. Under 4-dimethylaminopyridine (DMAP) catalysis, 2-furoyl chloride was used to acylate the phenolic hydroxyl groups of estrone (E1) and estradiol (E2). The reaction was completed rapidly at room temperature, and the resulting derivatives exhibited markedly enhanced mass-spectrometric responses after optimization. Sample preparation was completed within 30 min, establishing a simple and rapid method based on 2-furoyl chloride derivatization for the determination of E1 and E2 by UHPLC-QTOF-MS. The method required only 50 μL of serum and provided linear ranges of 0.5-200 ng/mL for E1 and 0.5-450 ng/mL for E2, with the coefficients of determination (R²) of 0.9986 and 0.9998, respectively. The LOD and LLOQ for both two analytes were 0.1 and 0.5 ng/mL, respectively. The method was used to analyze several kinds of animal serum samples to evaluate its applicability, indicating that the method may be further extended to other authentic biological matrices.

Schlagwörter

Stichwörter der Autor:innen

Biological matrix analysisDerivatizationEstradiol (E2)Estrone (E1)UHPLC-QTOF-MS

Autor:innen und Institutionen

  • College of Veterinary Medicine, South China Agricultural University, Guangzhou, 510642, Guangdong, PR China.
  • Chimelong Group Co., Guangzhou, 511430, China.
  • Chimelong Group Co., Guangzhou, 511430, China. Electronic address: dgx@chimelong.com.
  • College of Veterinary Medicine, South China Agricultural University, Guangzhou, 510642, Guangdong, PR China. Electronic address: ghwang@scau.edu.cn.

Zitieren

APA

Ding, Q., Zhang, T., Zhang, P., Chen, W., Li, J., Dong, G., & Wang, G. (2026). Detection of estrogens using 2-furoyl chloride derivatization coupled with ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry. Journal of Chromatography A, 467604. https://doi.org/10.1016/j.chroma.2026.467604

Vancouver

Ding Q, Zhang T, Zhang P, Chen W, Li J, Dong G, et al. Detection of estrogens using 2-furoyl chloride derivatization coupled with ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry. Journal of Chromatography A. 2026:467604. doi:10.1016/j.chroma.2026.467604

BibTeX
@article{Ding2026,
  author = {Ding, Qingyu and Zhang, Tianyou and Zhang, Peng and Chen, Weiye and Li, Jiayi and Dong, Guixin and Wang, Guanhua},
  title = {Detection of estrogens using 2-furoyl chloride derivatization coupled with ultra-high-performance liquid chromatography–quadrupole time-of-flight mass spectrometry},
  journal = {Journal of Chromatography A},
  year = {2026},
  pages = {467604},
  doi = {10.1016/j.chroma.2026.467604}
}
Kostenlos starten →