EUVIMEDEUVIMED entdecken
Crossref

A pH-mediated stacking CE–MS method for the sensitive determination of clozapine and amisulpride drugs in high ionic strength biomatrices

Yanping Wei, Yueting Hu, Fan Yang, Yujie Zhang, Famin Ke, Jing Zeng

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2026.467448 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Yanping Wei und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, China; Precise Separation and Analysis of Pharmaceutical Complex Systems Key Labor…. Hauptthemen laut MEDLINE: Clozapine, Sulpiride, Mass Spectrometry, Antipsychotic Agents. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Natural Science Foundation of Sichuan Province, Science and Technology Department of Sichuan Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Online preconcentration in capillary electrophoresis (CE) is severely limited by the high ionic strength of biomatrices, which eliminates the conductivity gradient required for field-amplified stacking. pH-Mediated stacking overcomes this problem by injecting a strong acid plug to neutralize matrix anions, thereby restoring field amplification for efficient on-column enrichment. In this work, a pH-mediated stacking CE method was developed for the simultaneous determination of the atypical antipsychotics clozapine and amisulpride in plasma, achieving sensitivity enhancement factors of approximately 114-fold for clozapine and 220-fold for amisulpride over conventional capillary zone electrophoresis. Upon coupling with MS detection, the method was fully validated. Both analytes exhibited good linearity over 5 to 400 ng/mL (R² ≥ 0.9926), with LODs of 1 ng/mL and LOQs of 5 ng/mL. Intra- and inter-day precision (RSD) were below 10% for peak areas and below 1.34% for migration times, and accuracy (RE) was within ±10%. Analysis of patient plasma samples yielded relative differences of 0.9% (clozapine) and 2.8% (amisulpride) compared with UHPLC-MS/MS, confirming good agreement between the two methods. These results indicate that pH-mediated stacking CE-MS provides a practical alternative to UHPLC-MS/MS for therapeutic drug monitoring, with comparable sensitivity, minimal sample consumption, and requiring only liquid-liquid extraction without additional offline enrichment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClozapineSulpirideMass SpectrometryAntipsychotic AgentsElectrophoresis, CapillaryAmisulprideHydrogen-Ion ConcentrationOsmolar ConcentrationReproducibility of ResultsHumansSensitivity and SpecificityLimit of Detection

Stichwörter der Autor:innen

Capillary electrophoresis–mass spectrometryOnline preconcentrationTherapeutic drug monitoringph-mediated stacking

Substanzen

ClozapineSulpirideAmisulprideAntipsychotic Agents

Autor:innen und Institutionen

  • School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, China; Precise Separation and Analysis of Pharmaceutical Complex Systems Key Laboratory of Luzhou, Sichuan, China; Institute of Sichuan Jincheng Judicia…
  • School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, China; Precise Separation and Analysis of Pharmaceutical Complex Systems Key Laboratory of Luzhou, Sichuan, China.
  • Judicial Authentication Center of Southwest Medical University, Luzhou, Sichuan, China.
  • Sichuan Provincial Luzhou Public Security Bureau, Luzhou, Sichuan, China.
  • School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, China; Precise Separation and Analysis of Pharmaceutical Complex Systems Key Laboratory of Luzhou, Sichuan, China. Electronic address: faminke@swmu.edu.…
  • School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, China; Precise Separation and Analysis of Pharmaceutical Complex Systems Key Laboratory of Luzhou, Sichuan, China; Judicial Authentication Center of Sou…

Förderung

  • Natural Science Foundation of Sichuan Province
  • Science and Technology Department of Sichuan Province
  • National Natural Science Foundation of China

Zitieren

APA

Wei, Y., Hu, Y., Yang, F., Zhang, Y., Ke, F., & Zeng, J. (2026). A pH-mediated stacking CE–MS method for the sensitive determination of clozapine and amisulpride drugs in high ionic strength biomatrices. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.467448

Vancouver

Wei Y, Hu Y, Yang F, Zhang Y, Ke F, Zeng J. A pH-mediated stacking CE–MS method for the sensitive determination of clozapine and amisulpride drugs in high ionic strength biomatrices. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.467448

BibTeX
@article{Wei2026,
  author = {Wei, Yanping and Hu, Yueting and Yang, Fan and Zhang, Yujie and Ke, Famin and Zeng, Jing},
  title = {A pH-mediated stacking CE–MS method for the sensitive determination of clozapine and amisulpride drugs in high ionic strength biomatrices},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2026.467448}
}
Kostenlos starten →