EUVIMEDEUVIMED entdecken
Crossref

Detection and confirmation of hypoxia-inducible factor activating agents in equine plasma and urine by liquid chromatography coupled to mass spectrometry

Fuyu Guan, Matthew A Adreance, Savannah Fay, Leif K McGoldrick, Bethany Keen, Youwen You, Mary A Robinson

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2026.467326 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Fuyu Guan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Sq…. Hauptthemen laut MEDLINE: Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Pennsylvania Department of Agriculture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hypoxia-inducible factor (HIF) activating agents can promote the transcription of the erythropoietin gene, enhancing an athlete's performance, and are therefore prohibited in sports. A liquid chromatography coupled to high-resolution mass spectrometry (LCHRMS) method was developed for the detection and confirmation of 11 HIF-activating substances in equine plasma and urine. Ammonium formate added to the mobile phase system suppressed the responses of all the analytes in either positive or negative ion mode and thus was not used. The starting organic percentage in the mobile phase gradient and sample reconstitution solution were optimized to minimize the carryover of the analytes. The analytes were extracted with solid-phase extraction. No interference from plasma or urine matrix was observed in the detection of the analytes by negative ion HRMS. Ten calibrators containing all 11 analytes at 10 to 10,000 pg/mL in plasma or urine were used to evaluate calibration ranges and limits of detection (LODs) by HRMS, and limits of confirmation (LOCs) by parallel reaction monitoring. LOD was 10 to 50 pg/mL for all analytes in plasma and 10 to 200 pg/mL in urine. LOC was 50 to 200 pg/mL for all analytes in plasma, except daprodustat and IOX 3 at 500 pg/mL, and 20 to 500 pg/mL in urine, except daprodustat and IOX 3 at 1000 pg/mL. The developed LC-MS method was successfully applied to the analysis of plasma and urine samples from a research horse following oral administration of JNJ 42041935.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liquid Chromatography-Mass SpectrometryAnimalsHorsesLimit of DetectionReproducibility of ResultsLinear ModelsChromatography, LiquidDoping in SportsSolid Phase Extraction

Stichwörter der Autor:innen

EnarodustatHypoxia-inducible factorJNJ 42041935TP 0463518prolyl-hydroxylase inhibitors

Autor:innen und Institutionen

  • Department of Clinical Studies, School of Veterinary Medicine, University of Pennsylvania, New Bolton Center Campus, 382 West Street Road, Kennett Square, PA, 19348, United States; Pennsylvania Equine Toxicology and Res…

Förderung

  • Pennsylvania Department of Agriculture

Zitieren

APA

Guan, F., Adreance, M. A., Fay, S., McGoldrick, L. K., Keen, B., You, Y., & Robinson, M. A. (2026). Detection and confirmation of hypoxia-inducible factor activating agents in equine plasma and urine by liquid chromatography coupled to mass spectrometry. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.467326

Vancouver

Guan F, Adreance MA, Fay S, McGoldrick LK, Keen B, You Y, et al. Detection and confirmation of hypoxia-inducible factor activating agents in equine plasma and urine by liquid chromatography coupled to mass spectrometry. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.467326

BibTeX
@article{Guan2026,
  author = {Guan, Fuyu and Adreance, Matthew A and Fay, Savannah and McGoldrick, Leif K and Keen, Bethany and You, Youwen and Robinson, Mary A},
  title = {Detection and confirmation of hypoxia-inducible factor activating agents in equine plasma and urine by liquid chromatography coupled to mass spectrometry},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2026.467326}
}
Kostenlos starten →