EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Novel applications of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detector for HPLC at ultraviolet wavelengths from 250 - 400 nm

Mostafa Almdaaf, Naser Bazina, Tariq Ahmed, Mosharraf Sarker, Meez Islam

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2026.467285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Mostafa Almdaaf und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Elmergib University, Al-Khums, Libya. Hauptthemen laut MEDLINE: Chromatography, High Pressure Liquid. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The first application of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection method for high performance liquid chromatography (HPLC) in the ultraviolet (UV) spectral range of 250–400 nm is reported. A custom-designed HPLC-BBCEAS system, incorporating a laser-driven light source (LDLS) and high reflectivity cavity mirrors (R ≥ 0.99), was employed for the separation and quantification of the polycyclic aromatic hydrocarbons (PAHs) anthracene and pyrene at near-UV wavelengths (300–400 nm). Minimum detectable absorption coefficients, α min(t) of 9.8 × 10⁻⁶ cm⁻¹ Hz⁻½ and 9.6 × 10⁻⁶ cm⁻¹ Hz⁻½ were achieved for anthracene and pyrene at 338 nm and 333 nm, respectively, with 6.8 × 10⁻⁶ cm⁻¹ Hz⁻½ observed for anthracene at 356 nm. These values correspond to 25-fold and 18-fold improvements in sensitivity compared to a conventional Perkin-Elmer HPLC-UV system. In the deep-UV region (250–300 nm), the separation and detection of vitamin D₂ and D₃ were demonstrated using both the LDLS and a 280 nm LED with R ∼ 0.96 cavity mirrors. LDLS-based measurements yielded α min(t) values of 5.1 × 10⁻⁴ cm⁻¹ Hz⁻½ and 4.0 × 10⁻⁴ cm⁻¹ Hz⁻½ for D₂ and D₃, respectively, while the LED measurements exhibited enhanced sensitivity with values of 7.7 × 10⁻⁵ cm⁻¹ Hz⁻½ and 5.8 × 10⁻⁵ cm⁻¹ Hz⁻½. These findings demonstrate that HPLC-BBCEAS enables broadband, multiplexed, and highly sensitive detection of UV-absorbing analytes and extends the practical detection range of HPLC into the deep-UV region.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromatography, High Pressure LiquidAnthracenesCalcifediolCholecalciferolPolycyclic Aromatic HydrocarbonsPyrenesReproducibility of ResultsSpectrophotometry, Ultraviolet

Stichwörter der Autor:innen

Broadband cavity enhanced absorption spectroscopy (BBCEAS)High performance liquid chromatography (HPLC)Polycyclic aromatic hydrocarbons (PAHs)Ultraviolet (UV) spectroscopyVitamin D2 and D3 detection

Substanzen

anthraceneAnthracenesCalcifediolCholecalciferolPolycyclic Aromatic HydrocarbonspyrenePyrenes

Autor:innen und Institutionen

  • Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Elmergib University, Al-Khums, Libya.
  • School of Health and Life Sciences, Teesside University, Borough Road, Middlesbrough, TS1 3BA, United Kingdom; Libyan Biotechnology Research Centre, Tripoli, Libya.
  • School of Computing, Engineering and Digital Technologies, Teesside University, Borough Road, Middlesbrough, TS1 3BA, United Kingdom. Electronic address: t.ahmed@tees.ac.uk.
  • School of Pharmacy and Biomolecular Sciences, Liverpool John Moores University, Liverpool, United Kingdom.
  • School of Health and Life Sciences, Teesside University, Borough Road, Middlesbrough, TS1 3BA, United Kingdom. Electronic address: m.islam@tees.ac.uk.

Zitieren

APA

Almdaaf, M., Bazina, N., Ahmed, T., Sarker, M., & Islam, M. (2026). Novel applications of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detector for HPLC at ultraviolet wavelengths from 250 - 400 nm. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.467285

Vancouver

Almdaaf M, Bazina N, Ahmed T, Sarker M, Islam M. Novel applications of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detector for HPLC at ultraviolet wavelengths from 250 - 400 nm. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.467285

BibTeX
@article{Almdaaf2026,
  author = {Almdaaf, Mostafa and Bazina, Naser and Ahmed, Tariq and Sarker, Mosharraf and Islam, Meez},
  title = {Novel applications of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detector for HPLC at ultraviolet wavelengths from 250 - 400 nm},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2026.467285}
}
Kostenlos starten →