EUVIMEDEUVIMED entdecken
Crossref

An isotopologue-mixture-based internal standard strategy for LC–MS/MS quantification in plasma

Ping Guo, Yuan Liu, Guozhu Liu, Ming Ma, Bo Chen

Journal of Chromatography A · 2026-08 · 1781 · 467069

DOI: 10.1016/j.chroma.2026.467069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026-08. Verfasst von Ping Guo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research of the Ministry …. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Hunan Provincial Innovation Foundation for Postgraduate, National Natural Science Foundation of China, Science and Technology Program of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stable isotope-labeled internal standards (SIL-IS) are the gold standard for liquid chromatography-tandem mass spectrometry (LC-MS/MS) quantification in complex biological matrices. Their application can be limited by synthetic complexity, high cost, and the lack of commercially available labeled standards for many bioactive analytes. Here, we establish and evaluate an internal-standard strategy based on hydrogen-deuterium exchange (HDX)-derived deuterated isotopologue mixtures. Using Pd/C, Pt/C, and AlCl₃ catalytic systems, deuterated isotopologue mixtures (d₁-dₙ) of eight structurally diverse bioactive compounds were prepared by HDX in deuterated methanol and characterized by ¹H NMR and LC-MS. Isotopologues with a mass difference of Δm ≥ 3 were selected as internal-standard candidates to minimize overlap with analyte M + 1/M + 2 isotopic peaks. Isotopic-distribution screening and chromatographic evaluation showed that eligible d₃-dₙ isotopologues co-eluted with their corresponding analytes (Δt < 0.01 min), with no appreciable chromatographic isotope effect (CIE). In plasma, LC-MS/MS validation showed linearity over 1-500 ng/mL (R² ≥ 0.995), limits of detection of 0.003-0.080 ng/mL and limits of quantification of 0.01-0.25 ng/mL. Trueness ranged from 85% to 115%, while precision, expressed as relative standard deviation (RSD), was ≤8% intra-day and ≤12% inter-day. Ratio-based matrix effect (ME%) values ranged from 85% to 112%. Using clenbuterol hydrochloride as a model analyte, the isotopologue-mixture-derived internal standard showed calibration performance comparable to that of the commercial deuterated standard clenbuterol-d₉. Compared with quantification based on external calibration without internal-standard normalization, the proposed approach reduced quantitative deviation from 15 to 25% to

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryReference StandardsHumansReproducibility of ResultsDeuteriumDeuterium Exchange Measurement

Stichwörter der Autor:innen

Deuterated isotopologue mixturesHydrogen–deuterium exchangeInternal standardsLC–MS/MS quantificationPlasma

Substanzen

Deuterium

Autor:innen und Institutionen

  • Key Laboratory of Phytochemical R&D of Hunan Province and Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research of the Ministry of Education, Hunan Normal University, No 36 Lushan Road, Changsha 410…
  • Institute of Bast Fiber Crops, Chinese Academy of Agricultural Sciences, Changsha 410014, China.
  • Changsha Chenchen Pharmaceutical Technology Co., Ltd., Changsha 410221, China.

Förderung

  • Hunan Provincial Innovation Foundation for Postgraduate
  • National Natural Science Foundation of China
  • Science and Technology Program of Hunan Province
  • China Hunan Provincial Science and Technology Department

Zitieren

APA

Guo, P., Liu, Y., Liu, G., Ma, M., & Chen, B. (2026). An isotopologue-mixture-based internal standard strategy for LC–MS/MS quantification in plasma. Journal of Chromatography A, 1781, 467069. https://doi.org/10.1016/j.chroma.2026.467069

Vancouver

Guo P, Liu Y, Liu G, Ma M, Chen B. An isotopologue-mixture-based internal standard strategy for LC–MS/MS quantification in plasma. Journal of Chromatography A. 2026;1781:467069. doi:10.1016/j.chroma.2026.467069

BibTeX
@article{Guo2026,
  author = {Guo, Ping and Liu, Yuan and Liu, Guozhu and Ma, Ming and Chen, Bo},
  title = {An isotopologue-mixture-based internal standard strategy for LC–MS/MS quantification in plasma},
  journal = {Journal of Chromatography A},
  year = {2026},
  volume = {1781},
  pages = {467069},
  doi = {10.1016/j.chroma.2026.467069}
}
Kostenlos starten →