EUVIMEDEUVIMED entdecken
Vergleichsstudie

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Donghyun Ryoo, Emily A Smith, Jared L Anderson

Journal of Chromatography A · 2026-05 · 1775 · 466917

DOI: 10.1016/j.chroma.2026.466917 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Chromatography A, 2026-05. Verfasst von Donghyun Ryoo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Iowa State University, Ames, IA 50011, USA; Ames National Laboratory-U.S. Department of Energy, Ames, IA, 50011, USA. Hauptthemen laut MEDLINE: Ionic Liquids, Siloxanes, Organophosphorus Compounds. Die Arbeit nennt 61 Literaturangaben. Gefördert von: Chemical Sciences, Geosciences, and Biosciences Division, Iowa State University, Basic Energy Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To assess whether the trihexyl(tetradecyl)phosphonium chloride ([P66614+][Cl-]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van't Hoff analysis. All van't Hoff plots for n-alkanes (C8-C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P66614+][Cl-] IL was further compared with the [P66614+] bis[(trifluoromethyl)sulfonyl]imide ([P66614+][NTf2-]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28-52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography-mass spectrometry (GC-MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34-40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P66614+][Cl-] IL providing enhanced separation between polar and aromatic analytes, while the [P66614+][NTf2-] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic-aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P66614+][Cl-] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P66614+]-based IL stationary phases compared to conventional stationary phase materials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ionic LiquidsSiloxanesOrganophosphorus CompoundsTemperatureChromatography, GasAlkanesThermodynamics

Stichwörter der Autor:innen

Chromatographic selectivityGas chromatographyIonic liquid stationary phasesPolysiloxane stationary phasesSummation of resolution metricsVan’t Hoff plots

Substanzen

Ionic LiquidsSiloxanesOrganophosphorus CompoundsAlkanes

Autor:innen und Institutionen

  • Department of Chemistry, Iowa State University, Ames, IA 50011, USA; Ames National Laboratory-U.S. Department of Energy, Ames, IA, 50011, USA.
  • Department of Chemistry, Iowa State University, Ames, IA 50011, USA; Ames National Laboratory-U.S. Department of Energy, Ames, IA, 50011, USA. Electronic address: andersoj@iastate.edu.

Förderung

  • Chemical Sciences, Geosciences, and Biosciences Division
  • Iowa State University
  • Basic Energy Sciences
  • Ames National Laboratory
  • U.S. Department of Energy

Zitieren

APA

Ryoo, D., Smith, E. A., & Anderson, J. L. (2026). Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases. Journal of Chromatography A, 1775, 466917. https://doi.org/10.1016/j.chroma.2026.466917

Vancouver

Ryoo D, Smith EA, Anderson JL. Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases. Journal of Chromatography A. 2026;1775:466917. doi:10.1016/j.chroma.2026.466917

BibTeX
@article{Ryoo2026,
  author = {Ryoo, Donghyun and Smith, Emily A and Anderson, Jared L},
  title = {Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases},
  journal = {Journal of Chromatography A},
  year = {2026},
  volume = {1775},
  pages = {466917},
  doi = {10.1016/j.chroma.2026.466917}
}
Kostenlos starten →