EUVIMEDEUVIMED entdecken
Crossref

Modeling retention time distribution in continuous Protein A affinity capture for materials traceability and diversion: A case study with twin-column system

Wu-Wei Chen, Liang-Zhi Qiao, Alois Jungbauer, Hai-Bin Qu, Shan-Jing Yao, Dong-Qiang Lin

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2026.466780 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Wu-Wei Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biolo…. Hauptthemen laut MEDLINE: Chromatography, Affinity, Staphylococcal Protein A, Models, Chemical. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Program of Zhejiang Province, National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biopharmaceutical industry is increasingly shifting from batch processing to continuous manufacturing. The ICH Q13 guideline outlines regulatory considerations for the implementation of continuous manufacturing with emphasis on material traceability. Although continuous capture with Protein A affinity chromatography is widely used, the aspect of material traceability remains underexplored. In this study, a retention time distribution (ReTD) model for a twin-column continuous capture process was developed, building on the single column model and the connection condition of the process to enable material traceability. The ReTD behaviors during the startup, interconnected load and disconnected load steps were simulated, focusing on how the material are distributed in the elution peaks across subsequent switches. These simulations were validated through tracer experiments using fluorescently labeled proteins as inert tracer, showing good agreement between the model predictions and experimental results. This observed ReTD behavior is attributed to the combination effects of breakthrough dynamics, exchange effects, and operational step changes. Based on the developed ReTD model, a method for materials traceability and diversion was proposed. The ReTD behavior for materials with extended durations can be extrapolated from materials with duration shorter than one switch, owing to the periodic nature of the continuous capture process. This ReTD-based approach allows for the tracking and evaluation of disturbance entering the system at any time, as well as their persistence for varying durations. These materials can then be diverted according to the acceptable limits, facilitating real-time product release. The proposed ReTD-based method offers a practical solution for ensuring material traceability and diversion, helping meet regulatory requirements and improving real-time product release in continuous capture processes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chromatography, AffinityStaphylococcal Protein AModels, ChemicalComputer Simulation

Stichwörter der Autor:innen

Continuous processMaterial traceabilityProtein A affinity chromatographyResidence time distributionRetention time distribution

Substanzen

Staphylococcal Protein A

Autor:innen und Institutionen

  • Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China.
  • Department of Biotechnology and Food Science, BOKU University, Vienna, Austria.
  • Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China.
  • Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China. Electr…

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Program of Zhejiang Province
  • National Key Research and Development Program of China

Zitieren

APA

Chen, W. W., Qiao, L. Z., Jungbauer, A., Qu, H. B., Yao, S. J., & Lin, D. Q. (2026). Modeling retention time distribution in continuous Protein A affinity capture for materials traceability and diversion: A case study with twin-column system. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2026.466780

Vancouver

Chen WW, Qiao LZ, Jungbauer A, Qu HB, Yao SJ, Lin DQ. Modeling retention time distribution in continuous Protein A affinity capture for materials traceability and diversion: A case study with twin-column system. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2026.466780

BibTeX
@article{Chen2026,
  author = {Chen, Wu-Wei and Qiao, Liang-Zhi and Jungbauer, Alois and Qu, Hai-Bin and Yao, Shan-Jing and Lin, Dong-Qiang},
  title = {Modeling retention time distribution in continuous Protein A affinity capture for materials traceability and diversion: A case study with twin-column system},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2026.466780}
}
Kostenlos starten →