EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasensitive detection of neurotransmitter dopamine in human urine via fluorescent azamonardine formed with resorcinol

Marianna Ntorkou, Paraskevas D Tzanavaras, Constantinos K Zacharis

Journal of Chromatography A · 2026

DOI: 10.1016/j.chroma.2025.466633 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2026. Verfasst von Marianna Ntorkou und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Pharmaceutical Analysis, Department of Pharmacy, Aristotle University of Thessaloniki GR-54124, Greece. Hauptthemen laut MEDLINE: Resorcinols, Dopamine, Fluorescent Dyes, Neurotransmitter Agents. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work presents a pre-column derivatization HPLC-spectrofluorimetric platform for the ultratrace quantification of endogenous dopamine (DA) in human urine. Under alkaline conditions, DA rapidly condenses with resorcinol to form a highly fluorescent azamonardine derivative (λex/λem = 420/460 nm), whose emission properties provide excellent analytical sensitivity in complex biochemical matrices. The derivatization proceeds quickly and yields a product with fluorescence stability for up to 6 hours. Key derivatization parameters were optimized using a face-centered central composite design. Selectivity studies confirmed the method's discriminative capability against major metabolic interferents (e.g., homovanillic acid), enabling accurate quantitation at low-ppb concentrations. Method validation was performed using accuracy profiles in accordance with FDA bioanalytical guidelines. The method exhibited linearity over 5-100 ng/mL with a limit of detection of 0.3 ng/mL. The method precision was less 3.5% in all cases. Environmental and operational performance were simultaneously assessed using the unified multicolor MA tool, demonstrating the method's strong sustainability profile and practical feasibility. Application to authentic human urine samples further confirmed the system's translational potential as a robust, high-performance analytical approach for clinical diagnostics, neurochemical studies, and broader bioanalytical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ResorcinolsDopamineFluorescent DyesNeurotransmitter AgentsHumansLimit of DetectionChromatography, High Pressure LiquidReproducibility of ResultsLinear ModelsSpectrometry, Fluorescence

Stichwörter der Autor:innen

Accuracy profilesDerivatizationDopamineHPLCResorcinolUrine

Substanzen

ResorcinolsDopamineresorcinolFluorescent DyesNeurotransmitter Agents

Autor:innen und Institutionen

  • Laboratory of Pharmaceutical Analysis, Department of Pharmacy, Aristotle University of Thessaloniki GR-54124, Greece.
  • Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki GR-54124, Greece.
  • Laboratory of Pharmaceutical Analysis, Department of Pharmacy, Aristotle University of Thessaloniki GR-54124, Greece. Electronic address: czacharis@pharm.auth.gr.

Zitieren

APA

Ntorkou, M., Tzanavaras, P. D., & Zacharis, C. K. (2026). Ultrasensitive detection of neurotransmitter dopamine in human urine via fluorescent azamonardine formed with resorcinol. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.466633

Vancouver

Ntorkou M, Tzanavaras PD, Zacharis CK. Ultrasensitive detection of neurotransmitter dopamine in human urine via fluorescent azamonardine formed with resorcinol. Journal of Chromatography A. 2026. doi:10.1016/j.chroma.2025.466633

BibTeX
@article{Ntorkou2026,
  author = {Ntorkou, Marianna and Tzanavaras, Paraskevas D and Zacharis, Constantinos K},
  title = {Ultrasensitive detection of neurotransmitter dopamine in human urine via fluorescent azamonardine formed with resorcinol},
  journal = {Journal of Chromatography A},
  year = {2026},
  doi = {10.1016/j.chroma.2025.466633}
}
Kostenlos starten →