EUVIMEDEUVIMED entdecken
Crossref

3D finite element simulation of continuous system for cells and bacteria separation using a combination of I-shaped deterministic lateral displacement arrays and acoustophoresis based on tilted-angle standing surface acoustic wave

Mehran Ebrahimi, Mohsen Rabbani

Journal of Chromatography A · 2025

DOI: 10.1016/j.chroma.2025.466090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Mehran Ebrahimi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, 8174673441 Isfahan, Iran. Hauptthemen laut MEDLINE: Lab-On-A-Chip Devices, Escherichia coli, Cell Separation, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 107 Literaturangaben. Gefördert von: FP7 Information and Communication Technologies, Ministry of Science Research and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microfluidic lab-on-a-chip technologies are revolutionizing diagnostic processes by enabling High-purity particle separation in heterogeneous mixtures, like blood, crucial for swift and accurate diagnoses, particularly in common diseases like cancer or infections where effective pathogen isolation is required. Passive deterministic lateral displacement (DLD) and active acoustophoresis are prominent microfluidic separation methods, each with distinct advantages and limitations. A hybrid approach, combining both, allows simultaneous utilization of their benefits, and enhances separation efficiency and purity through optimal design. A groundbreaking versatile 3D finite element (FE) model of an innovative-designed hybrid microfluidic device, featuring I-shaped DLD arrays and acoustofluidic module based on tilted-angle standing surface acoustic wave (TaSSAW) with focused interdigital transducers (FIDTs), has been presented, accurately predicting particles' behavior and separation dynamics. Simulations of individual devices were also conducted to optimize hybrid device performance, revealing high-efficiency and high-purity separation of polystyrene particles and bioparticles, including circulating tumor cells (MCF-7 CTCs), RBCs, and Escherichia coli bacteria. In the optimized acoustofluidic device, 15 µm polystyrene particles were separated with 100 % purity and 94 % efficiency, while MCF-7 CTCs were separated with 100 % purity and 98 % efficiency. The optimized DLD device achieved 100 % purity and efficiency for 2 µm and 8 µm polystyrene particles, RBCs, and bacteria. In the hybrid device, due to unpredictable factors, MCF-7 CTCs were isolated with 100 % purity but 40 % efficiency, while RBCs and bacteria maintained 100 % purity and efficiency. The results highlight the potential for further geometrical and fluidic optimizations to improve performance, with the 3D model providing a superior predictive tool compared to 2D models, facilitating cost-effective modeling of complex lab-on-a-chip structures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lab-On-A-Chip DevicesEscherichia coliCell SeparationMicrofluidic Analytical TechniquesHumansFinite Element AnalysisMCF-7 CellsEquipment DesignNeoplastic Cells, CirculatingErythrocytesSoundAcoustics

Stichwörter der Autor:innen

AcoustofluidicsDeterministic lateral displacementFinite element simulationHybrid particle/cell separationSurface acoustic wave

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, 8174673441 Isfahan, Iran.
  • Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, 8174673441 Isfahan, Iran. Electronic address: m.rabbani@eng.ui.ac.ir.

Förderung

  • FP7 Information and Communication Technologies
  • Ministry of Science Research and Technology

Zitieren

APA

Ebrahimi, M., & Rabbani, M. (2025). 3D finite element simulation of continuous system for cells and bacteria separation using a combination of I-shaped deterministic lateral displacement arrays and acoustophoresis based on tilted-angle standing surface acoustic wave. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.466090

Vancouver

Ebrahimi M, Rabbani M. 3D finite element simulation of continuous system for cells and bacteria separation using a combination of I-shaped deterministic lateral displacement arrays and acoustophoresis based on tilted-angle standing surface acoustic wave. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.466090

BibTeX
@article{Ebrahimi2025,
  author = {Ebrahimi, Mehran and Rabbani, Mohsen},
  title = {3D finite element simulation of continuous system for cells and bacteria separation using a combination of I-shaped deterministic lateral displacement arrays and acoustophoresis based on tilted-angle standing surface acoustic wave},
  journal = {Journal of Chromatography A},
  year = {2025},
  doi = {10.1016/j.chroma.2025.466090}
}
Kostenlos starten →