EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Microwave-assisted extraction of oxygen heterocyclic compounds from Citrus-scented creams using a deep eutectic solvent and their determination by HPLC-PDA

Giovanna Cafeo, Donatella Ferrara, Andrea Schincaglia, Marco Beccaria, Marina Russo, Luigi Mondello, Paola Dugo, Giorgia Purcaro

Journal of Chromatography A · 2025

DOI: 10.1016/j.chroma.2025.466085 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Giovanna Cafeo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, Universi…. Hauptthemen laut MEDLINE: Citrus, Deep Eutectic Solvents, Coumarins, Furocoumarins. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to investigate the content of oxygen heterocyclic compounds, especially coumarin and furocoumarins, in cosmetics products scented with Citrus essential oils. A minor component of the non-volatile fraction of Citrus essences is composed by oxygen heterocyclic compounds, commonly known as coumarins, furocoumarins, and polymethoxyflavones. These molecules show several biological effects on human health. On the other hand, coumarin has the potential to induce skin sensitization and furocoumarins show phototoxic activity. For this reason, several regulation and opinions have been issued concerning the maximum amount of these compounds in cosmetics. Given the regulatory framework, an analytical workflow for extraction and quantification of OHCs from cosmetics is necessary. This research aims to address this challenge by exploring, for the first time, a deep eutectic solvent as eco-friendly alternative for microwave-assisted extraction of these molecules from Citrus-scented creams. A deep eutectic solvent made by chloride and urea, at a molar ratio 1:2, and 20 % of water in weight was selected. Due to the complexity of the sample, a SPE clean-up was mandatory to obtain an extract devoid of interferents. Finally, an HPLC-PDA analytical method was employed allowing the simultaneous separation and quantification of 35 oxygen heterocyclic compounds in less than ten minutes. The analytical workflow here proposed was developed, optimized and validated demonstrating the potentials of deep eutectic solvents and microwaves in this field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CitrusDeep Eutectic SolventsCoumarinsFurocoumarinsHeterocyclic CompoundsMicrowavesChromatography, High Pressure LiquidReproducibility of ResultsLimit of DetectionLinear ModelsOils, Volatile

Stichwörter der Autor:innen

CosmeticsDeep Eutectic Solvents (DES)FurocoumarinsHPLC-PDAMicrowave-Assisted Extraction (MAE)

Substanzen

Deep Eutectic SolventsCoumarinsFurocoumarinsHeterocyclic CompoundsOils, Volatile

Autor:innen und Institutionen

  • Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc 98168 Messina, Italy.
  • Gembloux Agro-Bio Tech, University of Liège, Passage des Déportés 2, 5030 Gembloux, Belgium; Department of Pharmaceutical Science and Technology, University of Turin, via Pietro Giuria 9, 10125 Torino, Italy.
  • Gembloux Agro-Bio Tech, University of Liège, Passage des Déportés 2, 5030 Gembloux, Belgium; Department of Chemical, Pharmaceutical, and Agricultural Sciences, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara,…
  • Department of Chemical, Pharmaceutical, and Agricultural Sciences, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.
  • Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc 98168 Messina, Italy. Electronic…
  • Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc 98168 Messina, Italy; Chromaleon…

Zitieren

APA

Cafeo, G., Ferrara, D., Schincaglia, A., Beccaria, M., Russo, M., Mondello, L., Dugo, P., & Purcaro, G. (2025). Microwave-assisted extraction of oxygen heterocyclic compounds from Citrus-scented creams using a deep eutectic solvent and their determination by HPLC-PDA. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.466085

Vancouver

Cafeo G, Ferrara D, Schincaglia A, Beccaria M, Russo M, Mondello L, et al. Microwave-assisted extraction of oxygen heterocyclic compounds from Citrus-scented creams using a deep eutectic solvent and their determination by HPLC-PDA. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.466085

BibTeX
@article{Cafeo2025,
  author = {Cafeo, Giovanna and Ferrara, Donatella and Schincaglia, Andrea and Beccaria, Marco and Russo, Marina and Mondello, Luigi and Dugo, Paola and Purcaro, Giorgia},
  title = {Microwave-assisted extraction of oxygen heterocyclic compounds from Citrus-scented creams using a deep eutectic solvent and their determination by HPLC-PDA},
  journal = {Journal of Chromatography A},
  year = {2025},
  doi = {10.1016/j.chroma.2025.466085}
}
Kostenlos starten →