EUVIMEDEUVIMED entdecken
Crossref

Analysis of neutral per- and polyfluoroalkyl substances (PFAS) by gas chromatography ‒ high resolution mass spectrometry (GC HRMS)

Yelena Sapozhnikova, Kevin Stroski

Journal of Chromatography A · 2025-07 · 1753 · 465989

DOI: 10.1016/j.chroma.2025.465989 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2025-07. Verfasst von Yelena Sapozhnikova und 1 weiteren Autor:innen. Beteiligte Einrichtung: USDA, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA, USA. Electronic address: yelena.sapozhnikova@usda.gov. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Fluorocarbons. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Oak Ridge Institute for Science and Education, Agricultural Research Service, U.S. Department of Agriculture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Most of the studies on per- and polyfluoroalkyl substances (PFAS) to date encompass water soluble and ionic PFAS analyzed by liquid chromatography ̶ mass spectrometry, yet analytical methods and information on the occurrence of neutral PFAS are lacking. To this aim, we developed a new method for analysis of forty neutral PFAS using gas chromatography (GC) ̶ Orbitrap mass spectrometry with electron ionization (EI). Analytes were comprised of 29 fluorotelomer alcohols, 6 fluorotelomer acrylates and methacrylates, 3 perfluoroalkane sulfonamides and 2 perfluoroalkane sulfonamido alcohols. Gas chromatographic separation was developed on two GC phases: a standard non-polar (5 % diphenyl and 95 % dimethyl polysiloxane) and a mid-polar (6 % cyanopropylphenyl, 94 % dimethylpolysiloxane). A custom-made high-resolution mass spectral (HRMS) library was developed and used to evaluate PFAS accuracy of identification. Overall, 85 % of PFAS were correctly identified. A quantitative method was developed and evaluated for sensitivity, linearity, reproducibility, and ion interferences. Method sensitivity varied for different PFAS from 1 to 50 ppb based on the lowest calibrated levels. The developed method was utilized for analysis of PFAS in paper-based food contact materials after developing and evaluating the extraction protocol. Method applicability was demonstrated by analyzing paper-based food packaging samples, where 6:2 fluorotelomer alcohol was detected and measured at levels up to 351 ng/g. The developed GCHRMS method can be utilized for identification and measurement of neutral PFAS in various matrices, including food, dust, food contact materials, textiles and others.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gas Chromatography-Mass SpectrometryFluorocarbonsReproducibility of ResultsLimit of DetectionLinear Models

Stichwörter der Autor:innen

AcrylatesAnalysisFluorotelomer alcoholsGas chromatographyHigh resolution mass spectrometrySulfonamides

Substanzen

Fluorocarbons

Autor:innen und Institutionen

  • USDA, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA, USA. Electronic address: yelena.sapozhnikova@usda.gov.
  • USDA, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA, USA.

Förderung

  • Oak Ridge Institute for Science and Education
  • Agricultural Research Service
  • U.S. Department of Agriculture

Zitieren

APA

Sapozhnikova, Y., & Stroski, K. (2025). Analysis of neutral per- and polyfluoroalkyl substances (PFAS) by gas chromatography ‒ high resolution mass spectrometry (GC HRMS). Journal of Chromatography A, 1753, 465989. https://doi.org/10.1016/j.chroma.2025.465989

Vancouver

Sapozhnikova Y, Stroski K. Analysis of neutral per- and polyfluoroalkyl substances (PFAS) by gas chromatography ‒ high resolution mass spectrometry (GC HRMS). Journal of Chromatography A. 2025;1753:465989. doi:10.1016/j.chroma.2025.465989

BibTeX
@article{Sapozhnikova2025,
  author = {Sapozhnikova, Yelena and Stroski, Kevin},
  title = {Analysis of neutral per- and polyfluoroalkyl substances (PFAS) by gas chromatography ‒ high resolution mass spectrometry (GC HRMS)},
  journal = {Journal of Chromatography A},
  year = {2025},
  volume = {1753},
  pages = {465989},
  doi = {10.1016/j.chroma.2025.465989}
}
Kostenlos starten →