Detection of nonylphenol isomers in sewage and sludge of waste water treatment plant by GC-FID-MS combined with deans switch
Journal of Chromatography A · 2025
DOI: 10.1016/j.chroma.2025.465717 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2025. Verfasst von Lang Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou, 510006, China; Institute of Environmental Health and …. Hauptthemen laut MEDLINE: Sewage, Gas Chromatography-Mass Spectrometry, Phenols, Water Pollutants, Chemical. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Nonylphenols (NPs) are persistent endocrine-disrupting organic pollutant. Most studies focus on total NP content, with limited research on individual isomers. This study developed a method to separation and detection of 10 NP isomers using GC-FID-MS combined with Deans switch. It can effectively transfer NPs from the first gas chromatography column (DB-5MS) to the second column (CP-ChiraSil-DEXCB), achieving efficient separation of the 10 isomers. Sewage and sludge samples from wastewater treatment plants were prepared using solid-phase extraction (SPE) and solid-liquid extraction. NP isomers in sewage samples were enriched with a phenol-specific SPE column, rinsed with 10 mL methanol-water (v/v 2:8), and eluted with 3 mL methanol and 5 mL dichloromethane. NP isomers in sludge samples underwent three ultrasonic extractions with 30 mL ethyl acetate-dichloromethane (v/v 1:1). Concentrate the extract to 1 mL and then purified using an LCNH2 column, rinsed with 9 mL of ethyl acetate-n-hexane (v/v 1:9), and eluted with 10 mL of ethyl acetate-dichloromethane (v/v 1:1) .The results showed that the recovery rates for NP isomers ranged from 70.82 % to 110.12 % in sewage (LOQ: 0.09-0.31 μg/L; RSD: 1.82 %-10.12 %) and from 72.82 % to 114.12 % in sludge (LOQ: 0.15-0.47 μg/kg; RSD: 0.23 %-11.28 %), complying with the USEPA standards (70 %-130 %). Application of the method to real samples detected all 10 NP isomers, with concentrations of 0.50-5.01 μg/L in sewage and 0.13-24.91 μg/g in sludge.This method provides a reliable approach for the detection of NP isomers in complex environmental matrices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou, 510006, China; Institute of Environmental Health and Pollution Control, Guangdong-Hong Kong-Macao Joint Laboratory for Poll…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Liu, L., Zhang, J., Zhao, Y., & Ning, X. (2025). Detection of nonylphenol isomers in sewage and sludge of waste water treatment plant by GC-FID-MS combined with deans switch. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2025.465717
Vancouver
Liu L, Zhang J, Zhao Y, Ning X. Detection of nonylphenol isomers in sewage and sludge of waste water treatment plant by GC-FID-MS combined with deans switch. Journal of Chromatography A. 2025. doi:10.1016/j.chroma.2025.465717
BibTeX
@article{Liu2025,
author = {Liu, Lang and Zhang, Jianyi and Zhao, Yanqin and Ning, Xunan},
title = {Detection of nonylphenol isomers in sewage and sludge of waste water treatment plant by GC-FID-MS combined with deans switch},
journal = {Journal of Chromatography A},
year = {2025},
doi = {10.1016/j.chroma.2025.465717}
}
EUVIMED