Covalent organic frameworks with nitrogen-rich triazine units and suitable pore size for highly efficient adsorption and sensitive detection of bisphenols in water
Journal of Chromatography A · 2025-02 · 1743 · 465681
DOI: 10.1016/j.chroma.2025.465681 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2025-02. Verfasst von Xiaoli Zhou und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medici…. Hauptthemen laut MEDLINE: Triazines, Water Pollutants, Chemical, Phenols, Benzhydryl Compounds. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Natural Science Foundation.
Abstract (Originalsprache)
Herein, using 1,3,5-triformylphloroglucinol (Tp) and 4,4',4″-(1,3,5-triazine-2,4,6-triyl) tris(1,1'-biphenyl) trianiline (Ttba) as ligands, nitrogen-rich triazine unit-based covalent organic frameworks (COFs) with a suitable pore size, named TpTtba-COFs, were synthesized, and they were employed as adsorbents for the extraction and detection of three bisphenols (BPs)-BP A (BPA), BP B (BPB), and BP S (BPS)-in water. Using 2,4,6-tris(4-aminophenyl)-1,3,5-triazine (Tapt) and 1,3,5-tris(4-aminophenyl)benzene (Tapb) ligands as substitutes for Ttba, nitrogen-rich triazine unit-based COFs with a smaller pore size and nitrogen-poor triazine unit-based COFs, named TpTapt-COFs and TpTapb-COFs, respectively, were also prepared for comparison. The adsorption performances of the three COF adsorbents with regard to the three BPs were tested. Owing to nitrogen-rich triazine units and a pore size suitable for BP adsorption, the maximum adsorption capacities of TpTtba-COFs for BPA, BPB, and BPS were 1.13, 1.33, and 1.37 times those of TpTapt-COFs and 2.10, 2.27, and 1.92 times those of TpTapb-COFs, respectively. The adsorption behavior and possible adsorption mechanism of the BPs on the TpTtba-COFs were also investigated. In addition, a TpTtba-COF-based dispersive solid-phase extraction-high-performance liquid chromatography/ultraviolet method exhibited an excellent linear range (1-800 ng/mL) and satisfactory limit of detection values (0.20-0.32 ng/mL) for the three BPs. The spiked recoveries of the three BPs in river and lake water ranged within 81.9%-101.9% and 82.8%-100.8%, respectively. Overall, this study offers valuable insights into the rational design of adsorbents for adsorption and sensitive detection of BPs in environmental water.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Collaborative Innovati…
Förderung
- National Natural Science Foundation of China
- Guangxi Natural Science Foundation
Zitieren
APA
Zhou, X., Lai, X., & Hu, K. (2025). Covalent organic frameworks with nitrogen-rich triazine units and suitable pore size for highly efficient adsorption and sensitive detection of bisphenols in water. Journal of Chromatography A, 1743, 465681. https://doi.org/10.1016/j.chroma.2025.465681
Vancouver
Zhou X, Lai X, Hu K. Covalent organic frameworks with nitrogen-rich triazine units and suitable pore size for highly efficient adsorption and sensitive detection of bisphenols in water. Journal of Chromatography A. 2025;1743:465681. doi:10.1016/j.chroma.2025.465681
BibTeX
@article{Zhou2025,
author = {Zhou, Xiaoli and Lai, Xiaofen and Hu, Kun},
title = {Covalent organic frameworks with nitrogen-rich triazine units and suitable pore size for highly efficient adsorption and sensitive detection of bisphenols in water},
journal = {Journal of Chromatography A},
year = {2025},
volume = {1743},
pages = {465681},
doi = {10.1016/j.chroma.2025.465681}
}
EUVIMED